Removal Of The Compressor - Daikin G-Series Service Manual

Inverter multi for 2 rooms
Hide thumbs Also See for G-Series:
Table of Contents
SiBE12-933_A
1.7

Removal of the Compressor

Procedure
Step
Remove the terminal
1
cover.
Disconnect the flag-
2
shaped terminals.
Detach the terminals by
3
long nose pliers.
Release the hooks by a
flat screwdriver to
remove the overload
protector.
4
Detach the overload
protector.
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Terminal cover
Protection bushing
for lead wires
Yellow (V)
Be careful so as not to burn
the compressor terminals or
the name plate.
(R7637)
Red (U)
Blue (W)
(R7638)
(R7639)
(R7640)
Outdoor Unit
Points