Mitsubishi Electric PUHZ-W85VHA Installation Manual
Mitsubishi Electric PUHZ-W85VHA Installation Manual

Mitsubishi Electric PUHZ-W85VHA Installation Manual

Air to water heat pump
Hide thumbs Also See for PUHZ-W85VHA:
Air to Water Heat Pump
PUHZ-W85VHA

INSTALLATION MANUAL

For safe and correct use, read this manual as well as the indoor unit installation manual thoroughly before
installing the unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation die vorliegende
Bedienungsanleitung und die Installationsanleitung der Innenanlage gründlich durchlesen die Anlage.
MANUEL D'INSTALLATION
Avant d'installer l'unité, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil intérieur
pour une utilisation sûre et correcte.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het binnenapparaat zorgvuldig door voordat u met het
installeren van de unit begint.
MANUAL DE INSTALACIÓN
Para una utilización segura y correcta, lea este manual y el manual de instalación de la unidad interior
atentamente antes de proceder a la instalación de la unidad.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, leggere attentamente il presente manuale ed il manuale di installazione dell'unità
interna prima di installare l'unità.
EΓΧEIPIΔIO OΔHΓIΩN EΓKATAΣTAΣHΣ
Για ασφαλή και σωστή χρήση, διαβάστε προσεκτικά αυτό το εγχειρίδιο όπως και το εγχειρίδιο εγκατάστασης
της εσωτερικής μονάδας προτού εγκαταστήστε τη μονάδα.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade
interior antes de instalar a unidade.
INSTALLATIONSMANUAL
Læs af sikkerhedshensyn denne vejledning samt monteringsvejledningen til indendørsenheden grundigt, før
De monterer enheden.
INSTALLATIONSMANUAL
Läs bruksanvisningen och inomhusenhetens installationshandbok noga innan enheten installeras så att den
används på ett säkert och korrekt sätt.
MONTAJ ELKİTABI
Üniteyi kurmadan önce, güvenli ve doğru kullanım için bu kılavuzu ve iç mekan ünitesi kullanım kılavuzunu
dikkatle okuyun.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для обеспечения безопасной и надлежащей эксплуатации внимательно прочитайте данное
руководство и руководство по установке внутреннего прибора перед установкой прибора.
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
ΓΙΑ ΑΥΤΟΝ ΠΟΥ ΚΑΝΕΙ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ
PARA O INSTALADOR
TIL INSTALLATØREN
FÖR INSTALLATÖREN
MONTÖR İÇİN
ДЛЯ УСТАНОВИТЕЛЯ
English
Deutsch
Français
Nederlands
Español
Italiano
Eλληνικά
Português
Dansk
Svenska
Türkçe
Русский
Table of Contents
loading

Summary of Contents for Mitsubishi Electric PUHZ-W85VHA

  • Page 1: Installation Manual

    Air to Water Heat Pump PUHZ-W85VHA INSTALLATION MANUAL FOR INSTALLER English For safe and correct use, read this manual as well as the indoor unit installation manual thoroughly before installing the unit. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE Deutsch Aus Sicherheitsgründen und zur richtigen Verwendung vor der Installation die vorliegende Bedienungsanleitung und die Installationsanleitung der Innenanlage gründlich durchlesen die Anlage.
  • Page 2: Table Of Contents

    Im- other hazards. • Make sure to use accessories authorized by Mitsubishi Electric and ask properly installed unit may fall down and cause damages or injuries. • The unit must be securely installed on a structure that can sustain its an installer or an authorized technician to install them.
  • Page 3: Installation Location

    1. Safety precautions • Make sure to ground the unit. Do not connect the ground wire to gas or 1.3. Before electric work water pipes, lightning rods, or telephone grounding lines. If the unit is not Caution: properly grounded, there may be a risk to get an electric shock. •...
  • Page 4: Installation Procedure

    2. Installation location 2.4. NECESSARY SPACE TO INSTALL 2.4.1. When installing a single outdoor unit (Refer to the last page) Minimum dimensions are as follows, unless Maximum dimensions are indicated. Refer to the fi gures for each case. 1 Obstacles at rear only (Fig. 2-5) 2 Obstacles at rear and above only (Fig.
  • Page 5: Drainage Piping Work

    4. Drainage piping work Outdoor unit pipe connection Optional parts name Model name When drain piping is necessary, use the drain socket or the drain pan (option). Drain socket PAC-SG61DS-E Drain pan PAC-SG64DP-E 5. Water piping work 5.1. Water piping connection (Fig.5-1) •...
  • Page 6: Test Run

    6. Electrical work 6.2. Field electrical wiring Outdoor unit power supply ~/N (single), 50 Hz, 230 V Outdoor unit Circuit Breaker capacity 25 A Outdoor unit power supply, earth 3 × Min. 4 Interface unit/Flow temp. controller-Outdoor unit 3 × 1.5 (polar) Interface unit/Flow temp.
  • Page 7: Special Function

    8. Special Function 8.1. Low noise mode (on-site modifi cation) (Fig. 8-1) The low noise mode will be activated when a commercially available timer or the contact input of an ON/OFF switch is added to the CNDM connector (option) on the Brown control board of the outdoor unit.
  • Page 8 This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at hand is • Low Voltage Directive 2006/95/ EC based on the following • Electromagnetic Compatibility Directive EU regulations: 2004/108/EC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.

Table of Contents