WARNING
!
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
3. Screw the two threaded studs (supplied) into the
tapped holes in the hanger bracket.
4. Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 13).
5. Secure the ceiling cover in place by sliding
lockwashers over the threaded studs and installing
the two knurled knobs (supplied). (Figure 13.)
Tighten the knurled knobs securely until the ceiling
cover fits snugly against the ceiling and the hole in
the ceiling cover is clear of the downrod. Your fan
is now wired to be turned on and off from the fan
switch.
THREADED STUD
KNURLED KNOB
Figure 13
WARNING
!
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.
6. Cut the 3-speed switch pull chain to a desired
length (optional). Connect the wood pendant
(supplied) to the 3-speed switch pull chain by
sliding the wooden pendant (small hole first) onto
the pull chain. Attach the chain coupler to the end
of the chain and allow the wooden pendant to fall
down over the coupling.
1. Restore electrical power to the outlet box by turning
the electricity on at the main fuse box.
2. Check the operation of the light by gently pulling on
the light switch pull chain.
3. Check the operation of the fan by gently pulling on
the speed control switch pull chain. The operation
sequence is as follows:
1st pull - High
2nd pull - Medium
4. Your fan is shipped from the factory with the
reversing switch positioned to circulate air
downward. If airflow is desired in opposite
direction, turn the fan off and wait for the blades to
stop turning, then slide the reversing switch to the
opposite position, and turn the fan on again. The
fan blades will turn in the opposite direction and
reverse the airflow.
CEILING COVER
LOCKWASHER
8

Using Your Ceiling Fan

3rd pull - Low
4th pull - OFF
REVERSING
SWITCH
LIGHT PULL
CHAIN SWITCH
SPEED CONTROL
PULL CHAIN SWITCH