Specifications
Except where otherwise noted, the following specifications apply to both the
Switch 1600M and the Switch 2424M.

Physical

Width:
Depth:
Height:
Weight:
• Switch 1600M
• Switch 2424M

Electrical

The Switch 1600M and 2424M automatically adjust to any voltage between
100-127 and 200-240 volts and either 50 or 60 Hz.
AC voltage:
Maximum current:
• Switch 1600M
• Switch 2424M
Frequency range:

Environmental

Temperature:
Relative humidity:
(non-condensing)
Maximum altitude:
44.2 cm (17.4 in)
33.5 cm (13.2 in)
6.6 cm (2.6 in)
4.5 kg (9.9 lbs)
4.7 kg (10.4 lbs)
100–127 volts
200–240 volts
1.0 A
0.6 A
2.0 A
1.0 A
50/60 Hz
50/60 Hz
Operating
0°C to 55°C (32°F to 131°F)
15% to 95% at 40°C (104°F)
4.6 Km (15,000 ft)
Non-Operating
-40°C to 70°C (-40°F to 158°F)
15% to 90% at 65°C (149°F)
4.6 Km (15,000 ft)