Emerson TS1 Series Datasheet
Emerson TS1 Series Datasheet

Emerson TS1 Series Datasheet

Temperature controls

Quick Links

Adjustable temperature controls for refrigeration applications.
Features
Housing variants for top and front operation
Flush mounted version
Adjustable temperatures and differentials
Range and differential pointer in units °C and °F
Range and differential individually lockable by wire seal
High rated SPDT contacts for all versions
Captive terminal and cover screws
Manual toggle for system checkout and override
Vapour and x-ambient charges
Sensor shapes for various applications
Bellows heater for thermostats with vapour charge (not for
frost monitors)
Room thermostats with insulation console
Versions with and without manual override
Options
Gold plated contacts for electronic applications
(PLC, low voltage/current)
Factory set to customer specification
Different types of mounting brackets
Sensor bulb wells and capillary tube holders
Special approvals
Introduction
The TS1 Series is ALCO's range of adjustable thermostats for
application in refrigeration and heat pump systems.
In these systems, thermostats serve control and monitoring
functions, such as space temperature control, high/low
temperature alarming or defrost termination. By operating a set
of electrical contacts, a temperature value is kept inside a
certain limit.
Several housing variants and sensors are provided in order to
suit a control to a specific application.
Housing variants
TS1 controls can be delivered in three main housing variants,
top operated, front operated and flush mounted.
Top operated controls have adjustment spindles at the top and
a display scale, indicating temperature setpoint and differential,
at the front. A knob which may be permanently plugged onto
one of the adjustment spindles comes with every control. Frost
monitors and room thermostats are derivatives of top operated
thermostats. They differ by their sensors and other features to
suit their particular target applications.
Front operated controls have an adjustment knob at the front for
the temperature setpoint with an approximate scale imprinted
on
TS1__35038_EN_R05.doc
TS1 Series
Temperature Controls
D
A
T
A
S
H
TS1 Top Operated
TS1 Flush Mounted
the knob. In order to adjust the temperature differential, the
cover of the control must be removed.
Flush mounted controls are designed in a way that they can be
integrated into a panel or housing, for example into display
cases.
All of these three variants are available either with or without
off-switch, which cuts off power supply to the thermostat in off
position
Temperature sensing
TS1 thermostats sense temperature by means of a thermal
system, consisting of temperature charge, bulb, capillary and
bellows. The temperature charge changes its pressure based
on the refrigerant temperature to be sensed. The sensor is the
portion of the system which is in thermal contact with the
refrigerant, the capillary connects the sensor with the bellows
and the bellows contracts or expands depending on the
temperature, causing the thermostat to operate the electrical
contacts. An exception are capillary type of sensors, which do
not have a bulb, instead, their capillary serves as the bulb
directly.
1 / 8
Alco Controls
E
E
T
TS1 FrontOperated
10.08.2011
loading

Summary of Contents for Emerson TS1 Series

  • Page 1 TS1 Flush Mounted Special approvals Introduction The TS1 Series is ALCO’s range of adjustable thermostats for the knob. In order to adjust the temperature differential, the application in refrigeration and heat pump systems. cover of the control must be removed.
  • Page 2 TS1 Series Alco Controls Temperature Controls Setpoints Charges and sensor types are matched to temperature ranges and other application specific characteristics. TS1 thermostats TS1 are adjustable controls with adjustment spindles for range come with two charge types: vapour and adsorption charges.
  • Page 3 TS1 Series Alco Controls Temperature Controls Electrical contacts TS1 temperature controls are equipped with high rated double For operational safety, all TS1 with manual reset are designed as trip-free controls, i.e. pressing the manual reset button while snap action contacts for shatter-free and reliable operation.
  • Page 4 TS1 Series Alco Controls Temperature Controls Nomenclature The following chart explains the nomenclature of the TS1 Customised versions, which deviate from standard catalogue controls for ease of reference. The basic structure is that of a products are available on request and use a different Product three digit Product Name followed by a three digit code, Name.
  • Page 5 TS1 Series Alco Controls Temperature Controls Physical dimensions and drawings TS1-Axx / Bxx / Cxx / Dxx TS1-Exx / Fxx TS1-Gxx / Hxx Ø 22 Ø 9 Ø 9,5 Sensor type A Sensor type P Sensor type E Sensor type F...
  • Page 6 TS1 Series Alco Controls Temperature Controls Standard Temperature Controls Temperature controls should be selected such, that the target upper and lower setpoints fall well inside the adjustment range and not at the end of the specified range. Type Part Adjustment Range...
  • Page 7 TS1 Series Alco Controls Temperature Controls Type Part Adjustment Range Lowest Factory Max. Temp. Sensor Setpoint Charge Type Upper Differential Setting Bulb Setpoint Setpoint Temp. °C °C °C °C Thermostats TS1 Front Operated (with capillary type sensor) Thermostats without Off-Switch...
  • Page 8 This document replaces all earlier versions. Phone: Fax: Benelux +31 (0)77 324 0 234 +31 (0)77 324 0 235 Emerson Electric GmbH & Co OHG Germany, Austria & Switzerland +49 (0)6109 6059 -0 +49 (0)6109 6059 40 ALCO CONTROLS France, Greece, Maghreb...

This manual is also suitable for:

Alco controls ts1 seriesAlco controls ts1-a2pAlco controls ts1-a3pAlco controls ts1-a1aAlco controls ts1-a2aAlco controls ts1-a3a ... Show all