  • Page 1 Quick Start Guide 00825-0300-2654, Rev EA April 2019 ™ Rosemount Volume 1 Sensor Assembly...
  • Page 2: Wiring Diagrams

    April 2019 Quick Start Guide NOTICE This guide provides basic guidelines for Rosemount 0068, 0078, and 0183 Sensor models. It does not provide instructions for configuration, diagnostics, maintenance, service, troubleshooting, explosion-proof, flameproof, or intrinsically safe (I.S.) installations. If the Rosemount Volume 1 Sensor was ordered assembled to a temperature transmitter, see the appropriate transmitter Quick Start Guide for information on configuration and hazardous locations certifications.
  • Page 3: Drawings

    Quick Start Guide April 2019 Rosemount Series 58C sheath cutting 1. Determine the length to which the sheath will be cut. The finished length needs to include an additional 1.5-in. for compression fittings, or 2.5-in, for spring-loaded fittings (see Figure 2.
  • Page 4 April 2019 Quick Start Guide Figure 3. Rosemount Series 183 Thermocouple Wire Colors Type J Type E Type K Type T A. White B. Red C. Purple D. Yellow E. Blue Table 1. Rosemount Series 183 Thermocouple Characteristics Temperature range Thermocouple Thermocouple Limits of error (interchangeability)
  • Page 5 Quick Start Guide April 2019 Figure 4. Sensor Assembly D A B D A B B B A. Open identification tag L. Fla t or extended cover aluminum B. Standard adapter sensor assembly connection heads C. Sensor immersion length “X” M.
  • Page 6: Product Certifications

    A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount.. Ordinary Location Certification As standard, the transmitter has been examined and tested to determine that...
  • Page 7 Quick Start Guide April 2019 Specific Conditions of Use (X): 1. See certificate for ambient temperature range. 2. The non-metallic label may store an electrostatic charge and become a source of ignition in Group III environments. 3. Guard the LCD display cover against impact energies greater than 4 joules. 4.
  • Page 8 April 2019 Quick Start Guide EM Technical Regulations Customs Union (EAC) Flameproof Certificate: RU C-US.Gb05.B.00289 Markings: 1Ex d IIC T6…T1 Gb X Korea Korea Explosionproof/Flameproof Certificate: 13-KB4BO-0560X Markings: Ex d IIC T6…T1; T6(–50 °C ≤ T ≤ +40 °C), T5…T1(–50 °C ≤ T ≤...
  • Page 9 Quick Start Guide April 2019 Figure 5. Rosemount Series 68, 68Q, 78, and 58C Declaration of Conformity EU Declaration of Conformity No: RMD 1059 Rev. P Rosemount, Inc. 8200 Market Boulevard Chanhassen, MN 55317-9685 declare under our sole responsibility that the product, Rosemount™...
  • Page 10 April 2019 Quick Start Guide EU Declaration of Conformity No: RMD 1059 Rev. P ATEX Directive (2014/34/EU) FM12ATEX0065X - Flameproof Certificate Equipment Group II Category 2 G (Ex db IIC T6…T1 Gb) Harmonized Standards: EN60079-0:2012+A11:2013, EN60079-1:2014 FM12ATEX0065X - Dust Certificate Equipment Group II Category 2 D (Ex tb IIIC T130°C Db) Harmonized Standards: EN60079-0:2012+A11:2013, EN60079-31:2014...
  • Page 11 Quick Start Guide April 2019 China RoHS Rosemount 68/78/183 List of Rosemount 68/78/183 Parts with China RoHS Concentration above MCVs Hazardous Substances Hexavalent Polybrominated Polybrominated Part Name Lead Mercury Cadmium Chromium biphenyls diphenyl ethers (Pb) (Hg) (Cd) (Cr +6) (PBB) (PBDE) Electronics Assembly...
  • Page 12 Standard Terms and Conditions of Sale can be found on the Terms and Conditions of Sale page. +65 6777 0947 The Emerson logo is a trademark and service mark of Emerson [email protected] Electric Co. Rosemount and Rosemount logotype are trademarks of Emerson. Middle East and Africa Regional Office...