Note The Ambient Temperature And Ventilation; Installing And Connecting Up The Appliance - Bosch KFN91 Series Operating And Installation Manual

Table of Contents
Note the ambient
temperature and
ventilation
The climate class is stated on the
nameplate. It specifies the room
temperatures suitable for using the
appliance. The nameplate is on the
right of the appliance.
Climate class
Permissible ambient
temperature
+10 °C to 32 °C
SN
+16 °C to 32 °C
N
+16 °C to 38 °C
ST
+16 °C to 43 °C
T
Ventilation
The air from the base panel at the front
and cover plate at the rear heats up.
The heated air must be able to escape
unimpeded. Otherwise, the
refrigerating unit has to work harder,
which increases the appliance's power
consumption. You must therefore
never cover or block the ventilation
openings.
Installing and
connecting up the
appliance
The appliance must be installed
n
and connected up by a specialist in
accordance with these assembly
instructions.
Once the appliance has been
n
positioned, wait at least 8 hours
before plugging in the mains cable.
The oil in the compressor can shift
to the refrigeration system during
transport.
Before starting the appliance up for
n
the first time, clean its interior (see
section Cleaning the appliance").
The water line must be connected
n
up before the electrical
connections.
In addition to the statutory national
n
regulations, the connection
requirements of the local electricity
and water supply companies are to
be observed.
Only remove the transport locks on
n
the trays and racks once the
appliance has been installed.
If the appliance doors need to be
n
removed in order for the appliance
to fit through the doors of the
house or flat, the doors must be
removed by customer services only.
Water connection
Warning!
!
Risk of electric shock and of damage
to property!
Disconnect the appliance from the
electricity mains before carrying out
any work on the water connection.
The water connection must only be
installed by a qualified plumber in
accordance with the regulations
governing the plumbing trade and the
local waterworks.
Connect the appliance to a drinking
water pipeline.
Minimum pressure:
n
Maximum pressure:
n
If the water pressure is more than
8.2 bar, a pressure reducing valve
must be integrated. If the water
pressure is less than 1.0 bar, the ice
maker will not work.
The 3/4" tap for connecting the
enclosed connection line must be
easily accessible.
The connection line has a
3/4" connector.
The taste and smell of the water can
be improved by installing the enclosed
filter cartridge. If the filter cartridge is
used, pay attention to the different
connection conditions (see section
"Water filter").
Connecting up the appliance
1. Connect the connection line to the
appliance.
2. Connect the connection line to the
water tap.
3. Loop or wind the connection line so
that the appliance can be moved
away from the wall.
1.0 bar
8.2 bar
en
de
5