Troubleshooting - Emerson Premium CF4800WW03 Owner's Manual

Premium series, crown series
Hide thumbs Also See for Premium CF4800WW03:
Table of Contents
!
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER
BEFORE TROUBLE SHOOTING YOUR FAN.
TROUBLE
1. Fan will not start.
1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan,
2. Fan sounds noisy.
1. Blades not attached to fan.
2. Loose screws in motor housing.
3. Screws securing fan blade flanges to
4. Wire connectors inside switch housing
5. Screws holding blades to flanges are loose.
3. Fan wobbles
1. Setscrew in motor coupling is loose.
excessively.
2. Setscrew in hanger ball/downrod assembly
3. Screws securing fan blade flanges to motor
4. Fan blade flanges not seated properly.
5. Hanger bracket and/or ceiling outlet box
6. Fan blades out of balance.
1. Ceiling Fan Light Kits (see store or catalog).
2. Ceiling Fan/Light Controls (see store or catalog).
3. Downrod Extension Kits (see store or catalog).
WARNING
!
The use of any other control not specifically
approved for this fan could result in fire, shock and
personal injury.
Trouble Shooting
PROBABLE CAUSE
or loose switch wire connections in the
switch housing.
motor hub are loose.
rattling.
is loose.
hub are loose.
is not securely fastened.
Accessories
SUGGESTED REMEDY
1. Check main and branch circuit fuses or
circuit breakers.
WARNING: Make sure main power is
!
turned off.
2. Check line wire connections to fan and
switch wire connections in the switch
housing.
1. Attach blades to fan before operating.
2. Check to make sure all screws in motor
housing are snug (not over-tight).
3. Check to make sure the screws which
attach the fan flanges to the motor hub
are tight.
WARNING: Make sure main power is
!
turned off.
4. Check to make sure wire connectors in
switch housing are not rattling against
each other or against the interior wall of
the switch housing.
5. Tighten screws securely.
1. Raise motor cover and tighten setscrew
securely.
2. Tighten the setscrew in the hanger ball/
downrod assembly.
3. Check to be sure screws which attach
the fan blade flanges to the motor hub
are tight.
4. Check to be sure the fan blade flanges
seat firmly and uniformly to the surface
of the motor hub. If flanges are seated
incorrectly, loosen the flange screws and
retighten according to Step 15, 13, or 17
in Sections "A" or "B" Assembly
Instructions".
5. Tighten the hanger bracket screws to the
outlet box, and/or secure outlet box.
6. Interchanging an adjacent (side-by-side)
blade pair can redistribute the weight
and result in smoother operation. Or use
supplied balancing kit to balance blades.
!
This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Company. Substitution of parts or
accessories not designated for use with this product
by Emerson Company could result in personal injury
or property damage.