Emerson BELLA CF452AP00 Owner's Manual
Emerson BELLA CF452AP00 Owner's Manual

Emerson BELLA CF452AP00 Owner's Manual

52” ceiling fan
Hide thumbs Also See for BELLA CF452AP00:
READ AND SAVE THESE INSTRUCTIONS
52" Ceiling Fan Owner's Manual
CF452AP00 -
CF452AW00 -
CF452BS00 -
CF452GBZ00 -
CF452GES00 -
CF452ORB00 -
CF452SW00 -
CF452VNB00 -
CF452VS00 -
Part No. F40BP73980005
Revision: 131107
BELLA
Model Numbers
20.50
Net Weight:
Antique Pewter
Summer White
Brushed Steel
Gilded Bronze
Golden Espresso
Oil Rubbed Bronze
Satin White
Venetian Bronze
Vintage Steel
Lbs.
Form No. BP7398-5
U.L. Model No.: CF452
Table of Contents
loading

Summary of Contents for Emerson BELLA CF452AP00

  • Page 1 READ AND SAVE THESE INSTRUCTIONS BELLA ™ 52” Ceiling Fan Owner's Manual Model Numbers CF452AP00 - Antique Pewter CF452AW00 - Summer White CF452BS00 - Brushed Steel CF452GBZ00 - Gilded Bronze CF452GES00 - Golden Espresso CF452ORB00 - Oil Rubbed Bronze CF452SW00 - Satin White CF452VNB00 - Venetian Bronze...
  • Page 2: Table Of Contents

    3. Do not put anything into the fan blades while they are WARNING: To avoid fire, shock or injury, do not use an turning. Emerson or any other brand of control not specifically approved for this fan. 4. Do not operate reversing switch until fan blades have come to a complete stop.
  • Page 3: Unpacking Instructions

    Emerson Electric Co. Substitution of parts or accessories not designated for use with this product SWITCH HOUSING by Emerson Electric Co. could result in personal injury ASSEMBLY or property damage. HANGER BALL/ DOWNROD ASSEMBLY 1.
  • Page 4: Electrical Requirements

    1. Unpacking Instructions (continued) This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Installed Wire Length Wire Size A.W.G. Tools Needed for Assembly Up to 50 ft. One Phillips head screwdriver 50-100 ft.
  • Page 5: Ceiling Fan Assembly

    3. Ceiling Fan Assembly 1. Rotate the motor hub to align the hub motor area over each of the five shipping retainers. One by one unscrew each of the five screws and discard screws SWITCH HOUSING ADAPTER and shipping retainers (Figure 1). 2.
  • Page 6 3. Ceiling Fan Assembly (continued) 5. Remove and retain the three switch housing SWITCH HOUSING mounting screws (Figure 4) from the switch housing ASSEMBLY plate. Engage the connector of the switch housing assembly with the motor connector (Figure 4). The two connectors are keyed and color-coded and must be mated correctly (color-to-color) before they can be engaged.
  • Page 7 3. Ceiling Fan Assembly (continued) NOTE: The setscrews must be properly installed as described above, or fan wobble could result. MOTOR COUPLING SETSCREW WARNING HAIRPIN CLEVIS PIN CLIP It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened.
  • Page 8: How To Hang Your Ceiling Fan

    4. How to Hang Your Ceiling Fan WARNING CEILING The fan must be hung with at least 7' of clearance from floor to blades (Figure 11). AT LEAST WARNING FLOOR The outlet box and joist must be securely mounted and Figure 10 capable of supporting at least 50 lbs.
  • Page 9: How To Wire Your Ceiling Fan

    Securely connect wires with wire connectors supplied. CEILING NOTE: If you are using an Emerson Light Fixture COVER with your fan, see Light Fixture Owner’s Manual for wiring. 2. Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 13).
  • Page 10: Using Your Ceiling Fan

    Emerson Electric Co. Substitution of parts or accessories not designated for use with this product WARNING by Emerson Electric Co. could result in personal injury or property damage. The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.
  • Page 11: Energy Efficient Use Of Ceiling Fans

    8 - 9 feet above the floor for optimal occupied space. Remember to adjust your thermostat airflow. Consult your Emerson Retailer for optional when using your ceiling fan - additional energy and mounting accessories.
  • Page 12: Repair Parts

    10. Repair Parts U.L. Model No.: CF452...
  • Page 13 10. Repair Parts Listing Model Numbers Description CF452AP00 CF452AW00 CF452BS00 CF452GBZ00 CF452GES00 CF452ORB00 CF452SW00 CF452VNB00 CF452VS00 Hanger Ball Assembly, 761655-34 761655-21 761655-17 761655-77 761655-35 761655-32 761655-92 761655-89 761655-93 Consisting of: Hanger Bracket — — — — — — — — —...
  • Page 14: Trouble Shooting

    11. Trouble Shooting WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit 1.
  • Page 15: Ceiling Fan Limited Warranty

    What We Will Do To Correct Problems: If during the one (1) year warranty period the motor or any component or accessory of your Emerson Ceiling Fan is defective in materials or workmanship, or if during the expected lifetime of the Emerson Ceiling Fan (when used in accordance with the User Manual or other instructions) the motor is defective in materials or workmanship, you must contact Emerson during the applicable warranty period.
  • Page 16 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Questions, problems, missing parts: Before returning to the store call Emerson Electric Customer Service 8 a.m. - 6 p.m., Eastern, Monday-Friday 1-800-654-3545 www.emersonfans.com Retain this manual for future use.

Table of Contents