HP StorageWorks 7100 - Virtual Array Appendix

Appendix a. disk array controller log
Hide thumbs Also See for StorageWorks 7100 - Virtual Array:

Quick Links

Appendix A. Disk Array Controller Log

The array controller continually monitors all components of the disk array, and logs any information that may be of helpful in
evaluating the performance and operation of the array. All aspects of array operation are logged, including:
changes to the operating status of the array
changes to the configuration of the array
performance data
port error statistics
Table 1 lists all event codes that can appear in the controller log event pages. The table also includes events that are not
logged, but can still generate SCSI sense data. Appropriate corrective action is included for all events that require it. Many
events are informational and require no action on the part of the user. The Suspected Component column lists the hardware
components potentially implicated by the event code.
loading

Summary of Contents for HP StorageWorks 7100 - Virtual Array

  • Page 1: Appendix A. Disk Array Controller Log

    Appendix A. Disk Array Controller Log The array controller continually monitors all components of the disk array, and logs any information that may be of helpful in evaluating the performance and operation of the array. All aspects of array operation are logged, including: •...
  • Page 2 FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con Error! No text of specified style in document. Table 1. Controller Log Event Code Descriptions Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication 0/0x0 No Sense...
  • Page 3 Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication provided by CHECK_CONDITION, MEDIA_ERROR. The drive vendor PDD’s retries are exhausted. The PDD may or may not have attempted a REASSIGN BLOCKS command. 24/0x18 Disk Drive Hardware Error See information Disk Drive The disk drive returned a status of provided by...
  • Page 4 FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con Error! No text of specified style in document. Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication Command a PDM. This covers conflicts in both the device state in the PDM label and the sync state of the data effected by the down.
  • Page 5 Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication 51/0x33 Offline firmware download Ignore None An offline controller firmware download was with disk size derating attempted while disk size derating was in effect. Derating of the disks causes the shutdown portion of the offline download to post the shutdown image at the wrong location on the disk, and, as a result, the subsystem boots to a No Maps state after the...
  • Page 6 FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con Error! No text of specified style in document. Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication 70/0x46 Disk Interface Command N.A. None A backend device did not complete a command Timeout within the allotted time.
  • Page 7 Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication for LUN operation. controllers to complete the requested LUN operation. More memory must be installed before the requested operation can be completed successfully. 89/0x59 Undefined N.A. None Undefined event code. 90/0x5a Host Read Collision With ignore - see...
  • Page 8 FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con Error! No text of specified style in document. Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication count as one try of the I/O. 103/0x67 JM Write Recovered With Ignore - See...
  • Page 9 Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication parameters stored there will probably revert to their default values. 122/0x7a Hardware error prevents None of these are Unknown The command failed because a required access to successful command allowed hardware failed and was either not retried or was completion...
  • Page 10 FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con Error! No text of specified style in document. Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication accompanying Since volume set partitioning is not allowed the errors system cannot attach to this VS.
  • Page 11 Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication by a 0 indicates that the device number has not yet been assigned. 273/0x111 Disk Drive Added To Disk Set Ingore - Operator None This error code indicates the system state change activity consisting of the addition of a new volume set member.
  • Page 12 FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con Error! No text of specified style in document. Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication in the queue have been processed, the subsystem will undergo a short reset at which time the correctable error will be permanently corrected.
  • Page 13 Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication Problem - data transfer phase. This will cause disconnects to Unsupported be disabled for the entire on the interface, thus Disk causing degraded drive performance. This event may also indicate that the firmware could not enable queueing on this drive, which also causes disconnects to be disabled on the interface.
  • Page 14 FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con Error! No text of specified style in document. Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication used. 314/0x13a Drive Missing At Power On Ignore unless no Disk Drive, This error code indicates that a drive was discovered...
  • Page 15 Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication Failure Occurrance Controller, Manager (BGM) has discovered that there are not Backplane enough good fans to cool the system. The BGM is shuttingThe NVRAM is not posted to disk, so it is critical to repair the system quickly.
  • Page 16 FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con Error! No text of specified style in document. Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication 345/0x159 Bus A TWSI communication Controller, Either local controller or remote controller SRAM failure battery, power...
  • Page 17 Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication error appears in the first 4 bytes of the controller serial number field of this log record. The LUN appears in the fifth byte of the controller serial number, and the length of the affected area in 512 byte blocks appears in the last 3 bytes.
  • Page 18 FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con Error! No text of specified style in document. Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication controller download is sent to one of the controllers. This controller becomes the master of the download process.
  • Page 19 Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication is ErrEnR2. The tenth byte is ErrDR2. 381/0x17d LCC Installed Ignore - Operator LCC, Back End This error code indicates the system state change Activity FC Port, consisting of an LCC hot plug insertion. The device Controller number of the drive added appears in this change record.
  • Page 20 FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con Error! No text of specified style in document. Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication port. 405/0x195 Host FC Signal Detected Host Port An FC signal is now detected on the Host port.
  • Page 21 Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication download mode battery charger download mode to update the charger firmware 436/0x1b4 TWSI bus is busy Ignore, unless Controller The two-wire serial bus local to the controlle is occurring busy.
  • Page 22 FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con Error! No text of specified style in document. Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication 460/0x1cc TWSI Write Failure Controller, The two-wire serial bus module retried the write and battery, power- was either not able to get a response from the supply,...
  • Page 23 Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication The JEM object has completed its deletion. 481/0x1e1 LCC_JEM_DELETE_PENDI LCC/ESD Topology Manager requested a delete of a JEM NG_EH when the JEM has an outstanding I/O. The deletion is pending on the completion/failure of the outstanding I/O.
  • Page 24 FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con Error! No text of specified style in document. Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication revision that is unsupported by this firmware. 502/0x1f6 Enclosure NV memory controller...
  • Page 25 Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication 520/0x208 The over temperature error bit Power Supply The over current error bit is set in the power supply is set expander 521/0x209 The under voltage error bit is Power Supply The under voltage error bit is set in the power supply expander...
  • Page 26 FC-SCSI Interface SpecificationDescribes the IceCube SCSI interface. Targetted as part of OEM manual.Disk Array Con Error! No text of specified style in document. Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication 542/0x21e Disk interface is down Disk interface, Disk interface A disk interface has been down for longer than the disk or controller...
  • Page 27 Event Event Predictive Suspected Description Number Name Maintenance Components (dec/hex) Implication The actual blockSize is output in the verbose log eventInfo. 563/0x233 PDM Add Ignore Disk A PDM has been added for the specified device. This could mean that a previously downed drive is being re-added, or that a PDM was added for a newly added drive.