Removing The Cr Motor; Figure 3-54. Removing The Timing Belt Holder; Figure 3-55. Removing The Cr Motor - Epson C117001-N - DFX 5000+ B/W Dot-matrix Printer Service Manual

Terminal printer
Hide thumbs Also See for C117001-N - DFX 5000+ B/W Dot-matrix Printer:
Table of Contents

3.2.7.17 Removing the CR Motor

1.
Remove the printhead. (Refer to Section 3.2.1)
2. Remove the printer mechanism. (Refer to Section 3.2.6)
3. Remove the CP (PS) (M3 x 6) screw securing the timing belt holder and timing belt.
board assembly and unhook the CR motor cables at the base frame of the printer mechanism.
5. Remove the 3 CBS (SP) (M4 x 10) screws securing the CR motor to the right side frame and
remove the motor.
CBS
'
When you install the CR motor, perform the cam"age timing belt tension adjustment, as
described in Section 4.1.2.
When you install the printhead, perform the platen gap motor value (platm gap) adjus~t, as
described in Section 4.1.7.
Rev. A

Figure 3-54. Removing the Timing Belt Holder

Figure 3-55. Removing the CR Motor

Disassembly and Assambly
3-41
Table of Contents