Mounting Below a Suspended Ceiling

Mounting Below a Suspended Ceiling

To comply with NEC code, a #10-24 grounding lug is provided on the mounting bracket.
Note
You should review
Figure 3-2
1
2
3
Follow these steps to mount your access point on a suspended ceiling:
Step 1
Decide where you want to mount the access point.
Attach two T-rail clips to the suspended ceiling T-rail.
Step 2
Use the mounting bracket to adjust the distance between the T-rail clips so that they align with the holes
Step 3
in the mounting bracket.
Step 4
Use a standard screwdriver to tighten the T-rail clip studs in place on the suspended ceiling T-rail. Do
not overtighten.
Step 5
Install a plastic spacer on each T-rail clip stud. The spacer's legs should contact the suspended ceiling
T-rail.
Attach the mounting bracket to the T-rail clip studs and start a Keps nut on each stud.
Step 6
Cisco Aironet 1200 Series Access Point Hardware Installation Guide
3-4
Figure 3-2
before beginning the mounting process.
Mounting Bracket Parts
2
3
5
Suspended ceiling T-rail
T-rail clips
Plastic spacer
4
Mounting bracket
5
Keps nut (contains an attached lock washer)
Chapter 3
Mounting Instructions
1
2
3
4
5
OL-8370-04