Required Tools; Instructions - Left-Hand Unit (Sm0**-1Hz-*L*-**) - Bosch Greensource CDi Series Installation, Operation And Maintenance Manual

Table of Contents
SM Series Heat Pump
Blower configuration changes should be done prior
to unit being installed in the final location.

Required Tools

5/16" hex head driver
3/8" hex head driver
7/16" hex head driver
Flathead screw driver
Phillips screw driver
1/4" hex head driver
Needle nose pliers
5/16"-1/4" ratchet wrench
Instructions - Left-Hand Unit (SM0**-
1HZ-*L*-**)
1.
Remove and retain end and side panels.(Figure #6)
Figure # 6
2.
Disconnect blower motor wiring and ground wire
fastened to blower housing.(Figure#7)
Figure # 7
Revised 07-17
3.
Remove and retain bracket by removing (3) screws.
(Figure #8)
Figure # 8
4.
Loosen blower assembly by removing (4) screws.
(Figure #9)
Figure # 9
5.
Remove and retain bracket by removing (2) screws.
(Figure #10)
Figure # 10
Horizontal Configurability | 7
8733942411 (2017/06)
Table of Contents
loading

Table of Contents