Table of Contents

Quick Links

dormakaba
Combi B 90 with metal input unit
User Manual
- 02/2022
EN
Table of Contents
loading

Summary of Contents for Dormakaba Combi B 90

  • Page 1 Combi B 90 with metal input unit User Manual - 02/2022...
  • Page 2: Table Of Contents

    Opening the lock with configured OD and CW 6.4.3 Opening with Dual Mode 6.4.4 Opening with Duress Alarm 6.4.5 Lockout period 6.4.6 Closing the lock 6.4.7 Changing codes (P) 6.4.8 Opening with activated additional functions dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 3 Reconfiguring the lock via the PC software Special functions 6.6.1 Connecting the lock to the PC software 6.6.2 Additional functions via the signal inputs 6.6.3 Additional functions via the signal outputs Service Power supply Battery replacement - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 4: Glossary

    By using this code it is possible to open the lock during the assembly in the factory. User Code By using this code it is possible to open the lock. Users can also change their own code. dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 5: About This Document

    User Manual About this document 2 About this document 2.1 Purpose and objective This User Manual describes the Combi B 90 electronic safe locks with metal input unit. It gives information on: • The product and components • Functionality •...
  • Page 6: Safety Information

    Failure to observe this information may result in malfunctions. The device or something in its vicinity could be damaged. 3.3 Info Tips for usage, useful information which help to make the best use of the product and its functions. dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 7: Product Overview

    The lock is designed for use in the temperature range from +10° C to +50° C and with a humidity range from 30% to 80% (non-condensing). Operating elements of the input unit Actuating knob NUMERIC keys 0 ... 9 Keypad Enter key Red LED P key Green LED - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 8 Product overview User Manual Mini USB socket Mini USB socket Lock housing and interfaces Connections on the lock housing Power supply Connection for further components (e.g. EMA) Connection for input unit dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 9: Functionality

    - Activating, enabling, disabling or deleting User Codes and the Courier Code, even with activated Dual Mode - Activating or deactivating Dual Mode via PC software - Configuring or deleting OD / CW - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 10: Overview Of Commands

    Master (optionally executed by Activating or deactivating Dual Mode the Manager) Master Code Activating or deactivating Duress Alarm Acknowledging the tamper switch message Ermergency key Resetting the lock Re-assigning the Master Code dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 11: Overview Of Possible Signals

    Code is active and the acoustic signal sounds once The red light blinks 3 times and After pressing the ENTER key Code is active but disabled the acoustic signal sounds 3 times - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 12 User Manual Signal Occurrence of the signal Code status message Red light blinks once After pressing the ENTER key Code is deleted or inactive and the acoustic signal sounds once dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 13: Operation

    All pre-configured codes must be changed by the end user immediately after start-up. Opening the lock with the Setup Code Upon delivery the lock is set by dormakaba SAL GmbH to the Setup Code "1". The lock can be opened with the Setup Code until the lock system is put into operation.
  • Page 14: Configuration Functions Of The Master Code

    After changing the Master Code, the old Master Code is invalid. The functions of the new Master Code must be checked by opening the lock with the secure storage unit open. dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 15: Creating User Codes Or The Courier Code (P3)

    3 times and the acoustic signal sounds 3 times. if the red light blinks 3 times and the acoustic signal sounds 3 times after the first code entry, the code is already active. - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 16: Disabling User Codes Or The Courier Code (P4)

    6. Enter the ID to be enabled. ID = 01 to 89 for user or 95 for the courier Press the ENTER key. ð The green light turns off and the acoustic signal sounds twice. dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 17: Deleting User Codes Or The Courier Code (P5)

    00 = ID; X = valid 6-digit combination for the Master Code Press the ENTER key. ð The green light blinks twice and stays on, the acoustic signal sounds twice. Press P6. - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 18: Activating Od And Cw (P2)

    The red light blinks 3 times and the acoustic signal sounds 3 times if 00 is only defined either for OD or for CW. The activation of OD/CW is only possible with defined valid values. dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 19: Deactivating Od And Cw (P2)

    ð The green light turns off and the acoustic signal sounds twice. If the red light blinks twice and the acoustic signal sounds twice, Dual Mode has been deactivated before. All steps must be repeated to activated Dual Mode. - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 20: Deactivating Dual Mode (P7)

    ð The green light turns off and the acoustic signal sounds twice. If the red light blinks twice and the acoustic signal sounds twice, Duress Alarm has been deactivated before. All steps must be repeated to activate the Duress Alarm. dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 21: Deactivating Duress Alarm (P8)

    Before acknowledging the tamper switch message, make sure that the input unit has not been manipulated. If you are not sure, whether there has been a manipulation or not, consult an authorized service. - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 22: Configuration Functions Of The Manager Code

    User Manual 6.3 Configuration functions of the Manager Code The Manager Code must be activated with the PC software (see User Manual Combi B 90 PC software), otherwise the code with the ID 01 is a User Code. For security reasons, the configuration and testing of the configuration must always be performed with an opened secure storage unit.
  • Page 23: Creating User Codes Or The Courier Code (P3)

    ð The green light is on and the acoustic signal sounds twice. Press P4. 5. Press the ENTER key. ð The green light blinks twice and stays on, the acoustic signal sounds twice. - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 24: Enabling User Codes Or The Courier Code (P4)

    6. Enter the ID to be enabled. ID = 02 to 89 for user or 95 for the courier Press the ENTER key. ð The green light turns off and the acoustic signal sounds twice. dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 25: Deleting User Codes Or The Courier Code (P5)

    ð 1 code status message is generated for each ID. 8. Cancel the query mode by pressing PP. 9. Alternatively wait for 30 seconds. ð The red light blinks 3 times and the acoustic signal sounds 3 times. - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 26: Activating Od And Cw (P2)

    The function OD and CW for the Manager Code must be activated in the PC software (see User Manual Combi B 90 PC Software). Otherwise, this function is not available. Opening Delay (OD) is the time period which must elapse before it is possible to open the lock.
  • Page 27: Activating Dual Mode (P7)

    ð The red light blinks twice and the acoustic signal sounds twice. If the green light blinks twice and the acoustic signal sounds twice, Dual Mode has been activated before. All steps must be repeated to deactivate Dual Mode. - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 28: Lock Functions Of All Users

    5 seconds. ID = 00 to 89; = configured 6-digit combination for the corresponding ID Enter a valid opening code IDXXXXXX. 5. Press the ENTER key. dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 29: Opening With Dual Mode

    After a total of 3 incorrect code entries the lock switches to the lockout period. No matter if the first or the second code was entered incorrectly. - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 30: Opening With Duress Alarm

    Keep in mind that with the activated Dual Mode it is sufficient to enter both codes as Duress Codes to activate the Duress Alarm. However, the alarm is only activated if both codes required for opening have been entered completely. dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 31: Lockout Period

    If the red light blinks 3 times and the acoustic signal sounds 3 times after a second attempt to enter the new code for confirmation, the 2 codes entered do not match. - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 32: Opening With Activated Additional Functions

    Always mark first the position of the rotary knob for the assembly later, since the rotary knob can be inserted in steps of 90°. Use an adhesive tape on the input unit to mark the position of the marking on the rotary knob. dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 33 5. Pull out the rotary knob to the front from the input unit. 6. Remove the Allen wrench. Pull out the square shaft out of the lock. - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 34: Closing The Lock With The Emergency Key

    The o-ring must be installed approximately 5 to 8 mm at the end of the undrilled square shaft. Turn the emergency key to the stop counterclockwise through approximately 150°. Remove the emergency key. Secure the key against unauthorized access. dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 35: Changing The Master Code By Using The Emergency Key (P)

    ð The green light blinks twice and stays on, the acoustic signal sounds twice. Enter the new Master Code 00XXXXXX. 00 = ID; freely selected 6-digit combination (0...9) 5. Press the ENTER key. - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 36: Resetting The Lock (P0)

    Master Code. Only an audit entry is created. For further information on this procedure, refer to the User Manual Combi B 90 PC software. dormakaba Combi B 90 with metal input unit...
  • Page 37: Special Functions

    Reading-out audits – Configuring the lock settings For further information, see the User Manual Combi B 90 PC software. 6.6.2 Additional functions via the signal inputs The lock has an option which allows implementing additional functions via the signal input.
  • Page 38: Service

    12V power supply unit at the alarm box • If the lock is used without any signaling equipment: 9V power supply can be connected directly to the lock. dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 39: Battery Replacement

    Insert the Allen wrench up to the stop into the hole on the lateral wall of the input unit. 5. Pull out the rotary knob to the front of the input unit. 6. Remove the Allen wrench. - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 40 14. Mount the rotary knob in the position of the marking. ð If the mounting is correct, the rotary knob can no longer be removed. 15. Remove the marking. 16. Neutralize the tamper switch message with the Master Code. dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 41 User Manual Notes - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 42 User Manual dormakaba Combi B 90 with metal input unit - 02/2022...
  • Page 43 User Manual - 02/2022 dormakaba Combi B 90 with metal input unit...
  • Page 44 www.dormakaba.com...

Table of Contents