3.5 Change Combination ........................15 3.5.1 Change Combination – Display Keypad ....................15 3.5.2 Change Combination – Non-Display Keypad ..................16 3.6 Change Time/Date/DST ........................16 3.6.1 Change Time/Date/DST – Display Keypad..................16 dormakaba USA Inc. System User Guide 7040.0321 | 1...
Page 3
3.9.7 Duress Mode (Silent Alarm) ......................... 26 3.9.7.1 Duress Mode – Display Keypad ........................26 3.9.7.2 Duress Mode – Non-Display Keypad ......................27 3.10 Locks .............................27 3.10.1 Install a Lock ............................27 dormakaba USA Inc. System User Guide 7040.0321 | 2...
Page 4
4 System Security ..................35 4.1 Data Encryption ..........................35 4.2 Initial Combination Handling ......................35 5 LA GARD Software ................. 36 5.1 Adding a User ..........................36 5.2 Install a User into the Keypad ......................36 dormakaba USA Inc. System User Guide 7040.0321 | 3...
Page 5
5.3 Firmware Update ..........................37 5.4 Retrieve Audits ..........................37 5.5 Add Time Lock Schedules ......................38 Appendix A: # Commands ................. 39 Appendix B: List of Audits ................42 dormakaba USA Inc. System User Guide 7040.0321 | 4...
Ensure all power supplies are plugged into grounded electrical receptacles that comply with local building code(s). When AC mains power is required the power supply shall be installed in accordance with NFPA 70 and any applicable electrical codes. dormakaba USA Inc. System User Guide 7040.0321 | 5...
1.3 Tools dormakaba USA Inc. recommends having the following tools on hand to install LA GARD safe locks and their components: • Digital voltmeter • Wire cutters and needle nose pliers • Set of screwdrivers • Drill and drill bits •...
Battery box, alarm box, or AC adaptor LA GARD Keypad Figure 2 – Multi-Lock System Battery box, alarm box, or AC adaptor Lock #1 LA GARD Prgm Cable Multiplexor LA GARD Keypad dormakaba USA Inc. System User Guide 7040.0321 | 7...
A LA GARD 700 Series Battery Box accessory is available to be attached inside the secure container to grant power to the system • A LA GARD 700 Series Alarm Box can be connected to the primary lock to provide power to the system. This Alarm Box must be physically located in the secure side of the container •...
Time Delay 0-99 Min. 0-99 Min. 0-99 Min. 0-99 Min. Confirmation 1-60 Min. 1-60 Min. 1-60 Min. 1-60 Min. Window Time Delay Override (TDO) TDO with BLE Key Fob Programmable at Keypad dormakaba USA Inc. System User Guide 7040.0321 | 10...
Page 12
VdS 2396 – Pending Pending Pending Pending Pending Class 2 UL 2058 – UL Type 1 EN1300 – Level Pending Pending Pending Pending Pending SBSC – 3880- Pending Pending Pending Pending Pending 2015 dormakaba USA Inc. System User Guide 7040.0321 | 11...
Choose between a 12 and 24HR time format. Date Format Change the date format. Set Time Date Change the time and date. Select Enable/Disable to observe Daylight Saving Time Observe DST (DST). dormakaba USA Inc. System User Guide 7040.0321 | 12...
Page 14
Time Delay Override allowed and Reset. Enables a firmware update when connected to a PC running FW Update the LA GARD software client. FCC Label Display the FCC label information. *Not evaluated by UL dormakaba USA Inc. System User Guide 7040.0321 | 13...
4. Once “Installed”, there is no need to “wake up” the system before another intended key sequence. 3.3.3 Open a Lock – Display Keypad Follow these steps to open a safe lock on a Display Keypad: 1. Enter the User ID. dormakaba USA Inc. System User Guide 7040.0321 | 14...
Follow these steps to change a User combination on a Display Keypad: 1. From the Keypad display Main Menu, select Change combo. 2. New Combo appears on screen. Input a new combination with the number pad. dormakaba USA Inc. System User Guide 7040.0321 | 15...
2. To change DST, using the Keypad, input #63 + Authorized User ID and Combination + Enable DST (1) or Disable DST (0) + Return Key. 3. The Keypad will beep three times and flash a green LED once complete. dormakaba USA Inc. System User Guide 7040.0321 | 16...
The Master combination should be changed from the default value prior to adding any other non-Master Users to the System 3.8.1.2 Manager • Should be enabled within the system, but not required dormakaba USA Inc. System User Guide 7040.0321 | 17...
The user must present the FOB during an open sequence initiated by an authorized user(s). User may retrieve audits only. May not open the lock. User may open the lock only. dormakaba USA Inc. System User Guide 7040.0321 | 18...
Page 20
Daylight Saving Time (DST) Enable/Disable Set Date/Time View Audits on Keypad Retrieve Audits to PC Activate PC Link Assign Time Lock Access Schedule Enable/Disable Dual User Mode Enable/Disable Dual User Mode Applies to Managers dormakaba USA Inc. System User Guide 7040.0321 | 19...
Page 21
Time Delay: Delay Period Counting – up/down/none Time Delay: Open Period Counting – up/down/none Cancel Time Delay Duress Combo Enable/Disable per System Change Master Combination Access Audit Functions Master Manager User User User dormakaba USA Inc. System User Guide 7040.0321 | 20...
Follow these steps to edit a User on a Display Keypad: 1. Navigate through the Main Menu and select Users. 2. From the sub-menu, select Edit. 3. Input the User ID to be edited. dormakaba USA Inc. System User Guide 7040.0321 | 21...
1. Using the Keypad, input #56 + Authorized User ID and Combination + User ID to be Deleted + Return Key. 2. The Keypad will beep three times and flash a green LED. dormakaba USA Inc. System User Guide 7040.0321 | 22...
Power On – Keypad not Continuous alternate 1 long low beep Wrong Keypad Model Cannot Install compatible flashing red and green Master reset 3 short high beeps 3 short green flashes Reset Success dormakaba USA Inc. System User Guide 7040.0321 | 23...
4. Success Mode updated will appear on screen and the Keypad will beep twice and flash a green LED once complete. 3.9.3.2 Buzzer Mode – Non-Display Keypad Follow these steps to toggle the Buzzer Mode On and Off on a non-Display Keypad: dormakaba USA Inc. System User Guide 7040.0321 | 24...
3. From the list provided, select between Single, Dual and Dual + Mgr. 4. Success Mode updated will appear on screen and the Keypad will beep three times and flash a green LED once complete. dormakaba USA Inc. System User Guide 7040.0321 | 25...
3. Select between Yes and No to Enable/Disable Duress Mode. 4. Success Mode updated will appear on screen and the Keypad will beep three times and flash a green LED once complete. dormakaba USA Inc. System User Guide 7040.0321 | 26...
When a lock is reset, the Master Combination is reverted to the default (1-2-3-4-5-6-7-8) and all Managers/Users are deleted. All System and lock settings will be reset to their defaults. All locks will be uninstalled and unpaired to any Keypad. dormakaba USA Inc. System User Guide 7040.0321 | 27...
Follow these steps to Enable/Disable Time Delay on a Display Keypad: 1. Navigate through the Main Menu and select System. 2. Select Locks from the sub-menu. 3. Select TimeDelay. For multi-lock systems, select the corresponding lock number on the keypad dormakaba USA Inc. System User Guide 7040.0321 | 28...
1. Using the Keypad, input #72 + Authorized ID and Combination + Delay Period (00 to 99 minutes) + Open Window (01 to 60 minutes) + Return Key. 2. The Keypad will beep three times and flash a green LED once complete. dormakaba USA Inc. System User Guide 7040.0321 | 29...
3.11.3.2 Cancel a Time Delay – Non-Display Keypad Note: This function is not available on the 701 series of Keypad, Follow these steps to cancel a Time Delay on a non-Display Keypad: dormakaba USA Inc. System User Guide 7040.0321 | 30...
For multi-lock systems, select the corresponding lock number on the keypad If the selected lock has Time Delay and Time Delay Override enabled, and the User has Time Delay Override w/ Combo privileges for the lock, then the lock will open dormakaba USA Inc. System User Guide 7040.0321 | 31...
Lock allows Time Delay Override and the user has Override privileges, then the lock will open Time Delay will initiate for the selected lock • Selected Lock is in the Delay Period dormakaba USA Inc. System User Guide 7040.0321 | 32...
3 low beeps and 3 red LED flashes. Critical Low Battery will appear on screen with a critical low battery indicator if enough power remains. The System will not respond to any other commands until the battery is replaced. dormakaba USA Inc. System User Guide 7040.0321 | 33...
To view the codes defined for each audit, please refer to Appendix B. To retrieve Audits from a safe lock to the LA GARD Software client, refer to section 5.4 Retrieving Audits later in this document. dormakaba USA Inc. System User Guide 7040.0321 | 34...
Appendix A for the syntax of the # Commands. The failed error will be 3 red LED blinks and 3 low beeps. The firmware will enforce this requirement whenever the user is added, or the User’s combination is reset. This requirement does not apply to the Master user and combination. dormakaba USA Inc. System User Guide 7040.0321 | 35...
In the software client, select the Send icon located at the top-right of the screen. A progress bar will appear on screen. The Keypad will beep three times and flash a green LED once complete. dormakaba USA Inc. System User Guide 7040.0321 | 36...
Application for the Lock If there is ever an update, dormakaba will create the necessary files and distribute them appropriately. For entries with a display, navigate through the menus to find the current application FW levels of both the Keypad and any locks. Via a PC and software, the current levels of all four parts can be determined when doing a ‘Compare’...
11. In the software client, select the Send icon located at the top-right of the screen. A progress bar will appear on screen. The Keypad will beep three times and flash a green LED once complete. dormakaba USA Inc. System User Guide 7040.0321 | 38...
#1200123456781 Digit User Mode is defined as Mode user mode> 0 = Single User 1 = Dual User, does not apply to mgr 2 = Dual User, applies to mgr dormakaba USA Inc. System User Guide 7040.0321 | 39...
Page 41
654321. The 2 new Change own #5203123456036543210365 PIN> key> new PIN must match the ID of the Auth dormakaba USA Inc. System User Guide 7040.0321 | 40...
Page 42
#7403123456 user must be authorized to perform delay command. Note 1: Cancel Time Delay is only valid while Time Delay is active and only on Models that support the feature. dormakaba USA Inc. System User Guide 7040.0321 | 41...
Lock Firmware Update Started Bolt Opened Keypad Firmware Update Started Bolt Closed Time Delay Override Enabled Battery Low Time Delay Override Disabled Time Delay Overridden via Combo Wrong Try Penalty Started dormakaba USA Inc. System User Guide 7040.0321 | 42...