YOUR AIR PURIFIER

YOUR AIR PURIFIER

HOW YOUR AIR PURIFIER WORKS

This model air purifier incorporates a 3-stage cleaning system to help clean the air that passes through the filter in the unit (Fig. 1).
HOW YOUR AIR PURIFIER WORKS

Stage 1: Washable Pre-Filter

Stage 2: Permanent Washable IFD Filter

Stage 3: Electronic Ionizer

SET-UP

  • Select a firm, level and flat location. For proper airflow, locate the unit at least 3 feet (1 M) from any wall or furniture.
  • When operating, large volumes of air are drawn toward the air purifier. Surrounding areas should be cleaned and/or vacuumed frequently to prevent build-up of dust and other contaminates. This may also help prolong the life of the filter. If the unit is placed on a light colored carpet, a small mat or rug should be used underneath to prevent permanent staining. This is especially important in homes with contamination from smoking or fireplaces.

OPERATION

  • Ensure the air purifier is plugged into a working electrical outlet.
  • Press the power button () once. The unit will start at medium speed for a few seconds and then automatically change to low speed (Fig. 2).
  • Press the power button again to select a different cleaning level.

It is recommended you run your air purifier 24 hours a day to ensure continuous cleaning. Portable air purifiers are more effective in rooms where all doors and windows are closed.

ELECTRONIC FILTER CLEAN REMINDER

This model air purifier has an electronic filter check to remind you when to check and clean the washable IFD™ filter based on the air purifier's hours of use.

When the IFD™ filters need to be cleaned, the light will remain on until it is RESET. You may unplug the air cleaner without interrupting the filter check.

A red LED light will illuminate when it is time to clean the filter.

You should periodically check the filter. Depending on operating conditions, the filters should be cleaned at least once a month.

To RESET the Electronic Filter Check

When the filter monitor light remains on, it is time to check/clean the IFD™ filters and reset the filter monitor, if needed. With the unit powered on, insert the tip of a ball-point pen or paperclip next to the LED filter check light and hold for approximately 5 seconds until the light turns off (Fig. 3). Depending upon your individual usage (environment and hours used), you may need to check and clean the filters more or less frequently. If the IFD™ filters are cleaned before the filter monitor light turns on, the filter monitor should be reset at the same time.

These cleaning intervals are intended as guidelines only. Performance of any filter media is dependent upon the concentration of contaminates going through the system. High concentrations of contaminates such as dust, pet dander and smoking will reduce the useful performance of the filter.

OSCILLATION FEATURE

To help circulate fresher, cleaner air through the room, this unit has an oscillation feature.

  • To turn Oscillation on, simply press the Oscillation button () (Fig. 4).
  • To turn Oscillation Off, press the button again.

REMOVING THE FILTERS

The IFD filters are supplied within the air purifier.

  • Turn-off and unplug the air purifier. While pressing on the notches along the rear grille, pull the grille towards you and remove it (See Fig. 5). Gently push along the edge of the filter frame and pull forward. Repeat for the second filter.
  • Place back into the air purifier housing and snap filter grille into place.

CLEANING THE IFD™ FILTERS

To clean the IFDfilter:

  • After removing the IFD™ Filter from the air purifier, lay the filter on a flat surface and run a vacuum cleaner with a nozzle or brush attachment along the filter to pick-up tiny particles. Repeat on both sides (Fig. 6).

If your IFD™ filter appears to have dirt that has not been removed by tapping and vacuuming, please follow the steps below to wash the IFD™ filter.

  • Turn the power off and unplug the air purifier.
  • Remove the IFD™ filter from the unit.
  • Fill a sink with lukewarm water and add a few drops of mild dish soap.
  • Gently swish the filter in the soap solution to clean.
  • Soak the filter for 2-3 minutes. Do not leave for an extended period of time.
  • Rinse the filter with clean tap water (Fig. 7).
  • Shake the filter to remove any excess water.
  • Place the filter with the honeycomb side down on a plush towel.
  • Note that the filter may still be discolored even after washing. This is acceptable and will not affect performance.
  • Allow the IFD™ filter to dry for a few hours or overnight.
  • When the IFD™ filter is completely dry, place back into the air purifier.

  • Never place a wet IFD™ filter in your air purifier.
  • The IFD™ Filter is NOT dishwasher safe. Do not place the IFD™ filter in a dishwasher or subject it to other extreme hot water conditions.
  • Do not use any solvents, strong cleaning agents or flammable liquids to clean the IFD™ filter.

CLEANING THE PRE-FILTER

The particle pre-filter helps pick-up large airborne particles that enter the rear grille. This pre-filter can be removed and rinsed by hand under warm water (Fig. 8). Let the pre-filter dry completely before inserting it back into the unit.

CLEANING AND STORAGE

We recommend that you clean the air purifier at least once a month and before extended storage. Use only a dry cloth to wipe the external surfaces of the air purifier. DO NOT USE WATER, WAX POLISH, OR ANY CHEMICAL SOLUTION.

FREQUENTLY ASKED QUESTIONS

How often is cleaning required?

About every four weeks depending on the air quality of the room. You should clean your IFD™ filter regularly by gently running a vacuum attachment over it. We recommend washing the IFD™ filter when needed but not more than once a month.

How long should I run my Air Purifier?

For best results, you should operate your Air Purifier 24 hours a day. This unit will be more effective when doors and windows are closed.

ACCESSORIES AND REPLACEMENT FILTERS

To order replacement filters, visit our website at: www.kaz.com or call us at 1-800-477-0457. Washable Pre-Filter (T.3024): $5.25

CONSUMER RELATIONS

Mail questions or comments to:

Kaz, Incorporated
Consumer Relations Dept.
250 Turnpike Road
Southborough, MA 01772

Call us toll-free at: 1-800-477-0457
E-mail: [email protected]

Or visit our website at: www.kaz.com

Please be sure to specify a model number.

NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR WARRANTY. DO NOT RETURN TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE AIR PURIFIER OR PERSONAL INJURY.

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

  1. Read all instructions before operating the air purifier.
  2. Place air purifier where it is not easily knocked over by persons in the household.
  3. Always turn the air purifier controls to the OFF position and unplug from the wall outlet when not in use.
  4. To disconnect the model HFD-120 series air purifier, press the Power button to turn the unit off, grip the plug and pull it from the wall outlet. Never pull by the cord.
  5. Do not use any product with a damaged cord or plug or if product malfunctions, is dropped or damaged in any manner. Keep the cord away from heated surfaces.
  6. Do not use air purifier outdoors.
  7. Never use air purifier unless it is fully assembled.
  8. Do not run power cord under carpets, and do not cover with throw rugs. Arrange cord such that it will not be tripped over.
  9. Do not use air cleaner where combustible gases or vapors are present.
  10. Do not expose the air purifier to rain, or use near water, in a bathroom, laundry area or other damp location.
  11. The air purifier must be used in its upright position.
  12. Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the air purifier. Do not block air outlets or intakes.
  13. Locate air purifier near the outlet and avoid using an extension cord.
  14. This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
  15. A loose fit between the AC outlet (receptacle) and plug may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn outlet.
  16. Do not sit, stand or place heavy objects on the air purifier.
  17. Disconnect power supply before servicing.


To Reduce The Risk of Fire or Electric Shock, Do Not Use This Air Purifier With Any Solid-State Speed Control Device.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Need Assistance?

Do you have a question about the HFD-120 Series that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents