Chapter 4
[Output terminal function list]
Function
Symbol
Function name
code
Low-current
034
LOC2
indication signal
2
Overload notice
035
OL
advance signal 1
Overload notice
036
OL2
advance signal 2
037
BRK
Brake release
038
BER
Brake error
039
CON
Contactor control
0Hz speed
040
ZS
detection
Speed deviation
041
DSE
over
Position deviation
042
PDD
over
Positioning
043
POK
completed
Pulse count
044
PCMP
compare match
output
Deviation over
045
OD
for PID control
PID1 feedback
046
FBV
comparison
OD: Deviation
047
OD2
over for PID2
control
PID2 feedback
048
FBV2
comparison
Communication
049
NDc
line
disconnection
Analog [Ai1]
050
Ai1Dc
disconnection
detection
Analog [Ai2]
051
Ai2Dc
disconnection
detection
Analog [Ai3]
052
Ai3Dc
disconnection
detection
Analog [Ai4]
053
Ai4Dc
disconnection
detection
Analog [Ai5]
054
Ai5Dc
disconnection
detection
Analog [Ai6]
055
Ai6Dc
disconnection
detection
Window
056
WCAi1
comparator Ai1
Window
057
WCAi2
comparator Ai2
Window
058
WCAi3
comparator Ai3
Window
059
WCAi4
comparator Ai4
Window
060
WCAi5
comparator Ai5
Window
061
WCAi6
comparator Ai6
Description
ON if output current is less
than the setting value
[CE103].
ON if output current exceeds
specified value [CE106]
ON if output current exceeds
specified value [CE107]
ON when brake releases
ON if abnormality in sequence
happens.
This signal is used for power
line contactor control.
ON if output frequency is less
than set value [CE-33]
ON if speed deviation exceeds
the set value.[bb-82] [bb-83]
[bb-84]
ON if position deviation
exceeds the set value.[bb-85]
[bb-86] [bb-87]
ON if positioning is completed
ON when set value and pulse
train counter match.
[CA-97] to [CA-99]
ON if PID control deviation
exceeds the set value [AH-72]
ON if PID feedback is within
range. [AH-73] [AH-74]
ON if PID control deviation
exceeds the set value [AJ-17]
ON if PID feedback is within
range. [AJ-18] [AJ-19]
ON if communication is lost
with operation keypad
ON if Analog input 1 is less than
the set value [CE-50] [CE-51]
ON if Analog input 2 is less than
the set value [CE-52] [CE-53]
ON if Analog input 3 is less than
the set value [CE-54] [CE-55]
ON if Analog input 4 is less than
the set value [oE-44] [oE-45]
ON if Analog input 5 is less than
the set value [oE-46] [oE-47]
ON if Analog input 6 is less than
the set value [oE-48] [oE-49]
ON if Analog input 1 is within
range. [CE-40] to [CE-42]
ON if Analog input 2 is within
range. [CE-43] to [CE-45]
ON if Analog input 3 is within
range. [CE-46] to [CE-48]
ON if Analog input 4 is within
range. [oE-35] to [oE-37]
ON if Analog input 5 is within
range. [oE-38] to [oE-40]
ON if Analog input 6 is within
range. [oE-41] to [oE-43]
4-37
For parameter configuration
[Output terminal function list]
Function
Symbol
Function name
code
062
LOG1
Logical operation
result 1
063
LOG2
Logical operation
result 2
064
LOG3
Logical operation
result 3
065
LOG4
Logical operation
result 4
066
LOG5
Logical operation
result 5
067
LOG6
Logical operation
result 6
068
LOG7
Logical operation
result 7
General-purpose
069
MO1
output 1
General-purpose
070
MO2
output 2
General-purpose
071
MO3
output 3
General-purpose
072
MO4
output 4
General-purpose
073
MO5
output 5
General-purpose
074
MO6
output 6
General-purpose
075
MO7
output 7
Emergency force
076
EMFC
drive indicator
Bypass mode
077
EMBP
indicator
Trace function
078
WFT
waiting for trigger
Trace function data
079
TRA
logging
Low-battery of
080
LBK
keypad
Overvoltage power
081
OVS
Supply
084
AC0
Alarm code bit-0
085
AC1
Alarm code bit-1
086
AC2
Alarm code bit-2
087
AC3
Alarm code bit-3
Deviation over for
089
OD3
PID3 control
PID3 feedback
090
FBV3
comparison
Deviation over for
091
OD4
PID4 control
PID4 feedback
092
FBV4
comparison
093
SSE
PID soft start error
*1) It will be effective when you use the Liquid crystal
operator VOP (option).
Description
Determined
by
the
calculation results of two
output terminals
Set if case of use of EzSQ
ON while in force
operation
ON while in bypass
operation
This signal turns on until
the trace start triggers are
input.
ON while in data sampling.
ON while in low battery or
when keypad transfers no
clock data.
ON when overvoltage is
detected in stop status.
Alarm information is
output as bits by these
signals. *1)
ON when PID deviation
exceeds the value [AJ-37]
ON when PID feedback is
between [AJ-38]/[AJ-39]
ON when PID deviation
exceeds the value [AJ-57]
ON when PID feedback is
between [AJ-58]/[AJ-59]
ON when PID soft start
became in warning status