ROOM AIR CONDITIONER
MULTI SPLIT TYPE
(2 ROOMS)
HEAT & COOL MODEL
(REVERSE CYCLE)
INDOOR UNIT
ASH12RMACW
ASH7RMACW
OUTDOOR UNIT
AOH20RMBM2
INDOOR UNIT
ASH9RMACW
OUTDOOR UNIT
AOH19RSEM2
KEEP THIS OPERATION MANUAL
FOR FUTURE REFERENCE
FUJITSU GENERAL LIMITED
P/N9371436012
Table of Contents
loading

Summary of Contents for Fujitsu GENERAL ASH12RMACW

  • Page 1 MANUAL DE INSTRUÇÕES ROOM AIR CONDITIONER MULTI SPLIT TYPE (2 ROOMS) HEAT & COOL MODEL (REVERSE CYCLE) INDOOR UNIT ASH12RMACW ASH7RMACW OUTDOOR UNIT AOH20RMBM2 INDOOR UNIT ASH9RMACW OUTDOOR UNIT AOH19RSEM2 KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N9371436012...
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ........En-1 ADJUSTING THE DIRECTION OF FEATURES AND FUNCTIONS ......En-2 AIR CIRCULATION ..........En-11 NAME OF PARTS ..........En-3 SWING OPERATION ......... En-12 PREPARATION ............ En-5 MANUAL AUTO OPERATION ......En-12 OPERATION ............En-6 CLEANING AND CARE ........En-13 TIMER OPERATION ..........
  • Page 3: Features And Functions

    FEATURES AND FUNCTIONS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). AUTOMATIC OPERATION SWING OPERATION *G HEAT & COOL MODEL (REVERSE CYCLE) The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of Merely press the START/STOP button, and the unit will your room.
  • Page 4: Name Of Parts

    NAME OF PARTS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Fig. 1 Fig. 2 Fig. 3 Fig. 5 Fig. 4 Fig. 6 * HEAT & COOL MODEL (REVERSE CYCLE) COOLING MODEL Fig. 8 To facilitate explanation, the accompanying illustra- tion has been drawn to show all possible indicators;...
  • Page 5 Fig. 1 Indoor Unit Fig. 6 Remote Control Unit 1 Operating Control Panel (Fig. 2) H SLEEP button 2 POWER Switch I MASTER CONTROL button 3 MANUAL AUTO button J SET TEMP./SET TIME buttons ( K Signal Transmitter 4 Remote Control Signal Receiver L TIMER button 5 Indicator Lamps (Fig.
  • Page 6: Preparation

    PREPARATION CAUTION! Turn on the Power G Take care to prevent infants from accidentally swallowing batteries. Turn on the circuit breaker. G When not using the remote control unit for an extended period, remove the Set the POWER switch (Fig. 2 2) to ON. batteries to avoid possible leakage and damage to the unit.
  • Page 7: Operation

    OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). To Select Mode Operation Press the START/STOP button (Fig.6 N). The indoor unit’s OPERATION indicator lamp (red) (Fig. 3 6) will light. The air conditioner will start operating. Press the MASTER CONTROL button (Fig.6 I) to se- lect the desired mode.
  • Page 8 OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). When set to AUTO: * Heating : Fan operates so as to optimally circulate warmed air. However, the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low.
  • Page 9 AUTO: COOLING MODEL G Depending on the room temperature at the time operation begins, the operating mode will be switched automatically as shown in the accompanying table. Also, depending on the operating mode, the room temperature setting will cause the “standard” temperature to be set as shown. Actual Room Operating Mode Thermostat Setting...
  • Page 10: Timer Operation

    TIMER OPERATION Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (See page 5). To Use the ON timer or OFF timer To Cancel the Timer Press the START/STOP button (Fig. 6 N) Use the TIMER button to select “TIMER (if the unit is already operating, proceed to step 2).
  • Page 11: Sleep Timer Operation

    SLEEP TIMER OPERATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped. To Use the SLEEP timer To Cancel the Timer: While the air conditioner is operating or stopped, press the Use the TIMER button to select “TIMER...
  • Page 12: Adjusting The Direction Of Air Circulation

    ADJUSTING THE DIRECTION OF AIR CIRCULATION Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit’s AIR FLOW DIRECTION button. Hori- zontal (right-left) airflow direction is adjusted manually, by moving the Air Flow Direction Louvers. Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are stopped.
  • Page 13: Swing Operation

    SWING OPERATION Begin air conditioner operation before performing this procedure. To select SWING Operation Press the SWING LOUVER button (Fig. 6 P). The SWING indicator lamp (orange) (Fig. 3 8) will light. In this mode, the Air Flow Direction Louvers will swing automatically to direct the airflow both up and down.
  • Page 14: Cleaning And Care

    CLEANING AND CARE G Before cleaning the air conditioner, be sure to turn it off and disconnect the power supply cord. CAUTION! G Be sure the intake grille (Fig. 1 9) is installed securely. G When removing and replacing the air filters, be sure not to touch the heat exchanger, as per- sonal injury may result.
  • Page 15 TROUBLESHOOTING Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the WARNING! Power Supply Plug or turn off the circuit breaker, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source.
  • Page 16: Troubleshooting

    TROUBLESHOOTING Symptom Items to check See Page G Has the circuit breaker been turn off? CHECK ONCE Doesn’t operate at all: MORE G Has there been a power failure? — G Has a fuse blown out, or a circuit breaker been tripped? G Is the main POWER switch set to the OFF position? G Is the timer operating? G Is the air filter dirty?
  • Page 17 OPERATING TIPS Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle). In Event of Power Interruption AUTO Restart G If a power failure occurs during TIMER operation, the timer G The air conditioner power has been interrupted by a power will be reset and the unit will begin (or stop) operation at failure.
  • Page 18: Specifications

    SPECIFICATIONS MODEL INDOOR UNIT ASH12RMACW, ASH7RMACW ASH9RMACW OUTDOOR UNIT AOH20RMBM2 AOH19RSEM2 TYPE HEAT&COOL MULTI SPLIT TYPE (REVERSE CYCLE) POWER 220-240 V~ 50 Hz 220-240 V~ 50 Hz OPERATING INDOOR UNIT 12R + 7R 9R + 9R COOLING CAPACITY [kW] 3.45-3.45 2.25-2.25 5.70-5.70 2.65-2.70...