Quick Links

GE Energy
D400 Substation Data
Manager
User's Manual
994-0089
Version 1.00 Revision 2
General
Get other manuals https://www.bkmanuals.com
Table of Contents
loading

Summary of Contents for GE D400 Substation Data Manager

  • Page 1 GE Energy D400 Substation Data Manager User's Manual 994-0089 Version 1.00 Revision 2 General Get other manuals https://www.bkmanuals.com...
  • Page 2 GE Energy Copyright Notice © 2006-2007, General Electric Company. All rights reserved. The information contained in this online publication is the exclusive property of General Electric Company, except as otherwise indicated. You may view, copy and print documents and graphics incorporated in this online publication (the “Documents”) subject to the following: (1) the Documents may be used solely for personal, informational, non-commercial purposes;...
  • Page 3: Table Of Contents

    3 Setting up Communication Cards 4 Connecting to Devices and Networks 5 Powering Up the D400 6 Configuring the D400 7 Servicing the D400 A Standards & Protection B Ordering Guide D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 4 GE Energy 994-0089–1.00–2, General Get other manuals https://www.bkmanuals.com...
  • Page 5: About This Document

    Purpose This manual provides information about installing, setting up, using and maintaining your D400 Substation Data Manager. This manual does not provide any procedures for configuring the software of the D400. Note that some product features are not yet available and so these are marked as “Future”...
  • Page 6 GE Energy How to Use this Guide This guide describes how to install the D400 and get it up and running for the first time. Procedures are provided for all component options available for the D400. The components included in your D400 depend on what was ordered for your substation application.
  • Page 7: Product Support

    GE Energy Product Support If you need help with any aspect of your GE Energy product, you have a few options. Search Technical Support The GE Energy Web site provides fast access to technical information, such as manuals, release notes and knowledge base topics. Visit us on the Web at: www.ge.com/energy...
  • Page 8 RMA number. You will be sent the RMA number and RMA documents via fax or e-mail. Once you receive the RMA documents, attach them to the outside of the shipping package and ship to GE. Note: Product returns will not be accepted unless accompanied by the Return Merchandise Authorization number.
  • Page 9: Before You Start

    Turn off all power supplying the equipment in which the D400 is to be installed before installing and wiring the D400. • Beware of potential hazards and wear personal protective equipment. D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 10 GE Energy • The successful operation of this equipment depends upon proper handling, installation, and operation. Neglecting fundamental installation requirements may lead to personal injury as well as damage to electrical equipment or other property. • All AC voltage and current terminals are protected from accidental contact by a mechanical safety shield.
  • Page 11 D400 Power Supply Blank Assembly 520-0191 D400 Adapter Blank Assembly 520-0204 D400 650 MHz Celeron w Single Ethernet 520-0206 D400 USB KVM Assy 520-0207 D400 RS-232 IO Assy 520-0208 D400 RS-485 IO Assy D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 12 1000 ppm Product Overview The D400 Substation Data Manager is a secure, substation hardened and CE Marked communications gateway that polls metering, status, event and fault report data from intelligent electronic devices (IEDs). It summarizes the data from IEDs and makes it available to a master station or host computer over standard SCADA protocols.
  • Page 13 Built-in alarm annunciator • Support for time synchronization signals, including Network Time Protocol (NTP) and IRIG-B • Support for multiple SCADA protocols for communications to multiple masters • High-performance real-time database engine D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 14 GE Energy • Internal Mini SQL™ database for archival of SOE and alarm records • Built-in basic math/logic functions • IEC 61131-3 soft logic engine - Future • Event notification (e-mail) • Portable memory device plug-in • Dual CompactFlash cards for system and user storage •...
  • Page 15 Communications Protocols supported DNP3.0 Serial and UDP/TCP/IP, SEL Fast Meter Modbus® Serial and TCP/IP, IEC 870-5-101/104/103, Spabus, INCOM, GE Modem, BECO 2200, ASCII, SEL ASCII, IEC 61850 - Future DHCP, Telnet, NTP, HTTPS, SFTP, SSH, SSL, CHAP Network connections Single or dual redundant Ethernet interface...
  • Page 16 GE Energy Serial communications 16 channels: RS-232/RS-485/Fiber optic Data rate: 300 to 115.2 Kbps RS-232 Configurable for DCE/DTE operation Galvanic isolation Can drive IRIG-B signal to RS-232 ports (with optional IRIG-B Input card) RS-485 2-Wire/4-Wire support Galvanic isolation Fiber Optic Glass Optical Fiber serial port: (820-850 nm) 50/125 µm,...
  • Page 17 Overall height 2U (3.47”) [88.12 mm] Width 19” rack mount [482.59 mm] Depth 12.24” [310.95 mm] for chassis and rear connectors 13.04” [331.34 mm] with front clearance for protruding parts D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 18 GE Energy Environmental Operating temperature -20 °C to +65 °C Maximum ambient temperature is +50 °C for unit to fully comply with IEC 61010-1 Section 10.1 regarding surface temperature limits for protection against burns. Humidity rating 5 % to 95 % relative humidity, non-condensing...
  • Page 19: Installing The D400

    Make power connections and verify operation. See chapter “5 Powering Up the D400”. Install the supplied battery on the D400 main board. See chapter “7.2 Replacing the Battery”. Set up communications with the D400. See chapter “6 Configuring the D400”. D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 20 GE Energy Required Tools Before beginning the installation procedures, have the following tools and equipment available: • Ethernet cable(s) • Flathead screwdriver with 0.6 mm by 3.5 mm blade (for terminal block wiring) • Flathead screwdriver with 0.3 mm by 2.5 mm blade (for removing and installing the adapter cards and changing switch positions) •...
  • Page 21 • Mini SQL Proof of License Verify that you have received all items. GE parts include a unique GE part number, typically in the format XXX-XXXX, that can be used as a reference. Verify the hardware configuration of the D400 using the Product ID number. For an explanation of the Product ID, see Appendix B, “Ordering Guide”.
  • Page 22 GE Energy First Look at the D400 Front Panel The front panel of the D400 provides easy access to the status indicators, user connections and power supply units. Power Optional Redundant Supply Power Supply D400 Main Module User CompactFlash System Status...
  • Page 23 To mount the D400 in a panel: If you are using a panel cutout, use the following cutout dimensions: .162 in. 18.3 in. [464.8 mm] [4.1 mm] 17.5 in. [444.5 mm] Cutout for panel mounting D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 24: Setting Up Communication Cards

    The communication cards are powered from the backplane of the D400. D400 I/O Adapter Card Slots IRIG-B Distribution Slot Network Slots IRIG-B Input Slot USB KVM Slot Serial Communication Slots External Power Source Power Supply Alarms D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 25 4-Port Twisted-Pair Ethernet Switch • Hot Standby Fiber Optic Ethernet Switch • Redundant Twisted-Pair Ethernet + COM2 Port • COM2 Port USB KVM (Slot 13) • Keyboard, Video and Mouse D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 26 GE Energy Changing Card Settings The communication cards are factory installed with default settings. You may want to adjust individual card settings to work with your specific system set up. The communication cards are hot swappable -- this means you do not have to power down the D400 unit to remove and install the communication cards.
  • Page 27 GE Energy RS-232 Adapter The RS-232 Adapter (GE Part No. 520-0207) is a standard RS-232 serial I/O adapter card that plugs into any serial communication slot (slots 1 through 8) on the D400. It contains two independently isolated RS-232 serial ports (Port 1 J3 and Port 2 J2) each with a DB-9 connector.
  • Page 28 GE Energy RS-232 Adapter Top Side Switch SW1/SW2 Configuration Switches SW1 (for Port 2) and SW2 (for Port 1) control the signal type of the RS-232 port. Each switch contains five switch positions that can each be set to position A or B to select the appropriate port option.
  • Page 29 RS-232 Card Switch SW3/SW4 Settings SW3/SW4 Positions SW3/SW4 Positions Pin 6 Pin 4 Function Signal Signal DTE (default) DSR Input Output DSR Input Output IRIG-B IRIG-B Ground Enable Output D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 30 GE Energy DTE (Pin 4 DTR Output and Pin 6 DSR Input) DCE (Pin 4 DSR Input and Pin 6 DTR Output) IRIG-B Enable (on Pin 4) and Ground (on Pin 6) 994-0089–1.00–2, General Get other manuals https://www.bkmanuals.com...
  • Page 31 GE Energy RS-485 Adapter The RS-485 Adapter (GE Part No. 520-0208) plugs into any serial communication slot (slots 1 through 8) on the D400. It contains two independently isolated RS-485 channels on a single terminal block TB1: Channel 1 on terminals TB1-1 through TB1-5 and Channel 2 on terminals TB1-6 through TB1-10.
  • Page 32 GE Energy RS-485 Adapter Top Side RS-485 Adapter Bottom Side 994-0089–1.00–2, General Get other manuals https://www.bkmanuals.com...
  • Page 33 No Line termination between TX+ and TX- Not connected Line termination between RX+ and RX- No Line termination between RX+ and RX- Line termination between RX+ and RX- No Line termination between RX+ and RX- D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 34 Glass Optical Fiber (GOF) Serial with 820-850 nm ST connectors (GE Part No. 520-0209) • Plastic Optical Fiber (POF) Serial with 660 nm Agilent Versatile Link connectors (GE Part No. 520-0210) The Fiber Optic Serial cards include two pairs of channels for signal transmission (TX1/TX2) and reception (RX1/RX2) through ST or Versatile connectors.
  • Page 35 GE Energy Glass Optical Fiber Serial Adapter Plastic Optical Fiber Serial Adapter D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 36 GE Energy IRIG-B Input Adapter The IRIG-B Input Adapter (GE Part No. 520-0211) plugs into a dedicated IRIG-B slot (slot 9) on the D400. The IRIG-B Input card accepts an IRIG-B signal in one of three input formats through a corresponding connector type: •...
  • Page 37 ON or OFF to select the appropriate state. IRIG-B Input Card Switch SW3 Settings SW3 Switch Positions Fiber Optic TX Option Fiber RX (default) Inverted D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 38 GE Energy IRIG-B Distribution Adapter The IRIG-B Distribution Adapter (GE Part No. 520-0212) is an optional IRIG-B output card to supply an IRIG-B (TTL) signal passed from the IRIG-B Input card to attached IEDs. The IRIG-B Distribution card provides four channels on a single terminal block. Each channel is capable of supplying a signal to up to four IEDs, for a total of 16 IEDs.
  • Page 39 GE Energy 4-Port Twisted-Pair Ethernet Switch The 4-Port Twisted-Pair Ethernet Switch (GE Part No. 520-0213) is a 10/100BaseT network switch that plugs into the NET1 or NET2 slot (slots 11 and 12) on the D400. It provides local area network connections for up to five Ethernet connections: four RJ-45 connectors on the rear panel and one RJ-45 connector on the front panel.
  • Page 40 GE Energy Hot Standby Fiber Optic Ethernet Switch The Hot Standby Fiber Optic Ethernet Switch (GE Part No. 520-0214) is a 100BaseSX (820- 850 nm) network switch that supports single-IP redundancy for the D400. It provides automated fail over between two Ethernet fiber optic network connections (RX1/TX1 and RX2/TX2) that share a single MAC address.
  • Page 41 3.10 Redundant Twisted-Pair Ethernet + COM2 Port Adapter The Redundant TP Ethernet + COM2 Port card (GE Part No. 520-0218) provides two local area network connections with unique MAC addresses through Ethernet RJ-45 connectors. The LAN input routes to a three-port Ethernet switch and the WAN input routes to the PC/104-Plus Ethernet Module.
  • Page 42 GE Energy 3.11 COM2 Port Adapter The COM2 Port Adapter (GE Part No. 520-0219) provides a single DB-9 connector (P2) wired for an RS-232 DCE signal. The COM2 Port card can support serial connections for the following dial-up interfaces: •...
  • Page 43 GE Energy 3.12 USB KVM & Audio Adapter The USB Keyboard, Video, Mouse Adapter (GE Part No. 520-0206) plugs into the USB KVM slot (slot 13) on the D400. The card provides connections for setting up a permanent local workstation, including: •...
  • Page 44: Connecting To Devices And Networks

    “3 Setting up Communication Cards”. Serial The D400 can support up to 16 serial connections (up to 8 serial adapter cards with 2 ports each) to a variety of GE and other vendor devices, including: • Protective relays •...
  • Page 45 Optionally, a portable PC can be connected to the front Ethernet port to access the HMI locally. Local Maintenance A local PC can be directly connected to the D400 through a front serial communications port to perform system maintenance. D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 46 GE Energy Cabling Overview The D400 provides a series of I/O adapter cards for connecting cables and wiring from substation devices and network interfaces. All physical connections are made to easily accessible connectors on the rear panel of the D400.
  • Page 47 RS-232 and RS-485 connections must comply with the following requirements: • Cables must be shielded • D-type connector covers must provide EMC shielding (e.g. metalized plastic or die cast metal covers). D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 48 The D400 accepts connections to RS-232 type devices through the RS-232 Adapter. The RS-232 Adapter (GE Part No. 520-0207) is a standard RS-232 serial I/O adapter card that plugs into any serial communication slot (slots 1 through 8) on the D400. It contains two independently isolated RS-232 serial ports (Port 1 and Port 2) each with a DB-9 connector.
  • Page 49 The D400 accepts connections to RS-485 2-wire and 4-wire type devices through the RS- 485 Adapter. The RS-485 Adapter (GE Part No. 520-0208) plugs into any serial communication slot (slots 1 through 8) on the D400. It contains two independently isolated RS-485 channels on a single terminal block: Channel 1 on terminals TB1-1 through TB1-5 and Channel 2 on terminals TB1-6 through TB1-10.
  • Page 50 GE Energy RS-485 2-Wire Terminal Block Signal Definitions RS-485 Channel Position 2-Wire Number Function Signal Flow Channel 1 TX1+ IN/OUT TX1- IN/OUT FGND 1 RX1- RX1+ Channel 2 TX2+ IN/OUT TX2- IN/OUT FGND 2 RX2- RX2+ Note: The terminal block positions are numbered from 1 to 10 starting from the bottom of the card.
  • Page 51 To connect RS-485 4-wire type devices to the RS-485 Adapter, use the following wiring connection: Note: Before wiring devices, ensure that the RS-485 Adapter is configured to 4-wire mode (see section “3.4 RS-485 Adapter”). Device 1 Device 2 Device 3 D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 52 GE Energy RS-485 4-Wire Terminal Block Signal Definitions RS-485 Channel Position 4-Wire (default) Number Function Signal Flow Channel 1 TX1+ TX1- FGND 1 RX1- RX1+ Channel 2 TX2+ TX2- FGND 2 RX2- RX2+ Note: The terminal block positions are numbered from 1 to 10 starting from the bottom of the card.
  • Page 53 When calculating cable length, consider the following optical power levels: • Plastic optical fiber transmitter power is –9.0 ± 4.5 dBm • Plastic optical fiber receiver sensitivity is typically –39 dBm D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 54 TX and RX connectors. Hot Standby Fiber Optic Connections The Hot Standby Fiber Optic Ethernet Switch (GE Part No. 520-0214) is a 100BaseSX (820- 850 nm) network switch that supports single-IP redundancy for the D400. It provides automated fail over between two Ethernet fiber optic network connections (RX1/TX1 and RX2/TX2) that share a single MAC address.
  • Page 55 IRIG-B Input Adapter The IRIG-B Input Adapter (GE Part No. 520-0211) plugs into a dedicated IRIG-B slot (slot 9) on the D400. The IRIG-B Input card accepts an IRIG-B signal in one of three input formats through a corresponding connector type: •...
  • Page 56 IRIG-B Input Adapter IRIG-B Distribution Adapter The IRIG-B Distribution Adapter (GE Part No. 520-0212) is an optional IRIG-B output card to supply an IRIG-B (TTL) signal passed from the IRIG-B Input card to attached IEDs. The IRIG-B Distribution card provides four channels on a single terminal block. Each channel is capable of supplying a signal to up to four IEDs, for a total of 16 IEDs.
  • Page 57 D400. » To connect a local PC to the D400: Connect a straight-through Ethernet cable to your computer’s network communications port and to the D400's front Ethernet port. D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 58 GE Energy Ethernet RJ-45 Connector Signal Definitions Position Function Signal Flow Color White w/ Orange Orange White w/ Green Blue White w/ Blue Green White w/ Brown Brown Shield Ethernet Crossover Cable (RJ-45) Pin Out D400 Switch/Hub Name Name TX_D1+...
  • Page 59 See section “3.11 COM2 Port Adapter” for more information. » To connect a modem to the COM2 Port Adapter, use a straight-through modem cable (not supplied with the D400): Modem D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 60 GE Energy COM2 Port DB-9 Connector Signal Definitions Number Function Signal Flow Signal GND Not connected COM2 Port DB-9 to DB-25 Pin out Signal DB-9 DB-25 Pin # Pin # 994-0089–1.00–2, General Get other manuals https://www.bkmanuals.com...
  • Page 61 Connect the keyboard and mouse to the USB ports. Connect speakers (if available) to the audio jack. Tip: If the keyboard stops responding during use, simply unplug and re-connect the keyboard cable. D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 62 D400 to perform the initial setup of the D400 and to carry out maintenance and diagnostic procedures. The front maintenance port provides a direct serial connection to a PC using a serial null modem cable (GE Part No. 977-0529/72), which is supplied with the D400.
  • Page 63: Powering Up The D400

    The D400 supports one or two power supplies that provide 5 V to the D400 main module. The following power supplies may be provided in the Power Supply slots: • AC-DC power supply (GE Part No. 520-0217) • DC-DC power converter (GE Part No. 520-0216)
  • Page 64 GE Energy Redundant Power Supply The D400 may be provided with an optional redundant power supply unit in Power Supply Slot 2. The second power supply provides continuous power to the D400 in the event the primary power supply unit fails.
  • Page 65 The wires must be terminated with an insulated #6 Forked Terminal. The clear plastic protective barrier provided with the terminal strip connector must be in place once wiring of the mains is completed. D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 66 GE Energy External Power Requirements Before connecting an external power source to the D400, ensure that the following external power requirements are met: • An IEC 61010 qualified primary disconnect device and over current protection not exceeding 15 A must be externally provided in the AC/DC mains supply system.
  • Page 67 Two External AC First source Power Sources with connected to Optional Redundant SUPPLY1 D400 AC/DC Power terminals. Supply Second source connected to SUPPLY2 terminals. AC Power Source #1 AC Power Source #2 D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 68 GE Energy Power Source Connection Wiring Diagram Supply 1 Supply 2 Two External DC First source Power Sources with connected to Optional Redundant SUPPLY1 D400 DC Power terminals. Converter Second source connected to SUPPLY2 terminals. DC Power Source #1 DC Power Source #2 Connect protective earth wire to the Protective Earth terminal on the rear panel.
  • Page 69 Terminals 1 and 2 Absent Terminals 2 and 3 For proper connection, the recommended tool torque settings for power terminal screws are 10.8 in-lb [1.22 Nm]. Replace the terminal block protective plastic cover. D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 70 GE Energy Power Fail Alarm Connection Station Battery / Power Source Light ON when Light ON after operational failure System Fail The D400 includes a System Fail contact closure to provide an external LED indication on the system or LAN status.
  • Page 71 GE Energy System Fail Alarm Connection Station Battery / Power Source Light ON when Light ON after operational failure D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 72 GE Energy Front Panel LEDs Once the D400 is powered up, the LED indicators on the front panel of the D400 become active. The indicators provide status information on the operation of the D400. D400 Front LEDs System Status LEDs The System Status LEDs indicate the unit’s operational status:...
  • Page 73 • If a serial communication card slot is empty, (that is, no card is installed) the serial Receive (RXD) LED may be lit. D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 74: Configuring The D400

    » To connect to the D400: Connect the supplied null modem cable (GE Part No. 977-0529/72) to your computer’s serial communications port and to the D400's front communications port. See section “4.10 Front Maintenance Port” for cabling information.
  • Page 75 At the D400 login prompt, type the default username root and press Enter, and then type the default password geroot and press Enter. Note: When you enter the password, it may not be visible on the screen. The D400#>> system prompt displays. D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 76 GE Energy You are now online with the D400. » To configure the network interface: At the D400 #>> prompt, type D400cfg and press Enter. The D400 Configuration Utility menu appears. Type 2 and press Enter to select 2. Configure Network Interface.
  • Page 77 In this example, only one Ethernet interface card is installed in the D400 so only one Ethernet interface is available for configuration. Select 1. eth0. Type the IP address of the D400 and press Enter. D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 78 GE Energy The default IP address is 192.168.168.81. Enter the Subnet Mask of the D400. The default Subnet Mask is 255.255.255.0. Enter the DNS Server address. If the DNS Server address is not required, press Enter to continue. Enter the Gateway IP address. If the Gateway IP address is not required, press Enter to continue.
  • Page 79: Servicing The D400

    Unit has sustained no accidental physical damage • Airflow is not obstructed • Connectors and cables are intact and firmly attached • Battery condition is good Only trained personnel should perform maintenance on the D400. D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 80 GE Energy Removing the D400 Main Module You need to remove the D400 main module from the chassis to access the system battery and the system CompactFlash card for maintenance. D400 Main Module » To remove and re-insert the D400 main module: Power down the D400.
  • Page 81 You can access the battery compartment by removing the D400 main module from the chassis. The battery holder BT1 is located near the front corner of the board, behind the two rows of Serial Port Status LEDs. D400 Battery Location D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 82 GE Energy Before You Remove the Battery… Note the following items before you begin battery replacement. CAUTION • Disconnect power to the D400 before changing the battery. • Avoid exposure to high temperatures, such as soldering or spot-welding • Avoid excessive force to terminals •...
  • Page 83 D400 is powered down for extended periods or stored. For long-term storage: • Keep the equipment at temperatures and humidity below normal • Avoid shorting or loading while stored D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 84 GE Energy Changing the CompactFlash CompactFlash cards are designed with flash technology, a non-volatile storage solution that can retain data indefinitely without a battery. The cards are solid state, meaning they contain no moving parts, and provide much greater protection of data than conventional magnetic disk drives.
  • Page 85 Slide the new power supply unit into the chassis. Hand-tighten the two screws on the front panel. Verify that the Power LED is illuminated on the replaced power supply unit. D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 86: A Standards & Protection

    IEC 60255-22-2 IEEE C37.90.3 ® IEC 61000-4-3 Radiated, radio-frequency electromagnetic field immunity test IEC 60255-22-3 IEEE C37.90.2 (10 V/m) IEC 61000-4-4 Electrical fast transient/burst immunity test IEC 60255-22-4 IEEE C37.90.1 D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 87 Environmental Testing - Cold IEC 60068-2-2 Environmental Testing - Dry Heat IEC 60068-2-6 Environmental Testing – Vibration (sinusoidal) IEC 60255-21-1 IEC 60068-2-27 Environmental Testing - Shock IEC 60068-2-29 Environmental Testing - Bump D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 88 GE Energy Category Standard Name Description IEC 60068-2-30 Environmental Testing - Damp heat, cyclic (12 h + 12h cycle) IEC 60068-2-31 Environmental Testing - Drop and topple IEC 60255-21-2 Shock and bump tests Communication Standards IEEE 802.3 CSMA/CD Access Method (and physical...
  • Page 89: B Ordering Guide

    This ID number is composed of 400- followed by 16 alphanumeric characters that are determined by the options selected. The ID number is listed on a label located next to Slot 1 on the rear panel of the D400. D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 90 GE Energy D400 Ordering Guide Product Identification Number 400- CPU OPTIONS A – 650 MHz CPU, 512 MB RAM, SINGLE ETHERNET B – 650 MHz CPU, 512 MB RAM, DUAL REDUNDANT ETHERNET POWER SUPPLY SLOT 1 A – 100-240 VAC (47-63 Hz), 100-300 VDC (±10 %) B –...
  • Page 91 Added RoHS and recycling info, updated RS-485 channel numbering order Authentication Record Version Rev. Date Authenticator Scope of Authentication 1.00 Feb. 28, 2007 E. Stuhr Chapters 1-5, 7, Appendices A and B D400 Substation Data Manager User's Manual Get other manuals https://www.bkmanuals.com...
  • Page 92 Get other manuals https://www.bkmanuals.com...

Table of Contents