Hitachi SJ-FB Instruction Manual page 26

Feed-back board
Hide thumbs Also See for SJ-FB:
Table of Contents
(Note 3) : N/D must be given as the ranges of 1/50 ≤ (N/D) ≤ 20.
(N: Electronic gear ratio numerator, D: Electronic gear ratio denominator)
(Note 4) : It depends on what type of main body combines with the SJ-FB, the setting
value conversion is different. Please refer to the (Note 3) of the "5.3 Items
regarding the feed back board of the inverter main body".
Data setting of input-output terminals
Input-output terminal
The pulse train position
command input permission
signal. (STAT)
Positioning completion
signal.(POK)
Set '48' (the pulse train position command input permission signal (STAT)) to one of C001∼C008.
Pulse train position command input is valid only in the case that the STAT terminal is turned ON. In
the case that the STAT terminal is OFF or unestablished, pulse train position command input is
invalid.
Below the example of the proportion of the slave side turn number to the master side turn number
by the setting of P019 P021 is shown. (Yet, the encoder pulse number of the master side and slave
side are same and be in the case of 1024 pulses. )
Position selection for electronic gear (P019)
Numerator of ration setting for electronic gear (P020)
Denominator of ratio setting for electronic gear (P021)
Slave side turn number to the master side turn number
With terminal assignment
Set '48' to one of
C001∼C008
Set '23' to one of
C021∼C025
01 (REF)
1024
2048
26
Get other manuals https://www.bkmanuals.com
Chapter 7
Contents
Pulse train position command input
is valid while ON.
Output when it entered into the
positioning completion range
01 (REF)
00 (FB)
2048
1024
1024
2048
1/2
2
2
FUNCTIONS
00 (FB)
2048
1024
1/2
Table of Contents
loading