OPERATING TIPS
Instructions relating to heating (*) are applicable only to "HEAT & COOL MODEL" (Reverse Cycle).
Temperature and Humidity Range
Outdoor temperature
Indoor temperature
Indoor humidity
G If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may
operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of
lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
G Do not use this unit for any purposes other than the Cooling, (*)Heating, Dehumidifying, and air-circulation of rooms in
ordinary dwellings.
SPECIFICATIONS
MODEL
POWER
COOLING CAPACITY
HEATING CAPACITY
DIMENSIONS & WEIGHT
HEIGHT
WIDTH
DEPTH
WEIGHT
G
Acoustic Noise Information : The maximum sound pressure level is less than 70 dB (A) for both indoor unit and outdoor
En-7
COOLING MODEL
HEAT & COOL MODEL
HEAT RECOVERY MODEL
(Reverse Cycle)
AB 12TF
[kW]
3.40-3.50
[kW]
4.00-4.10
[mm]
[mm]
[mm]
[kg]
unit.
According to IEC 704-1 and ISO 3744.
Cooling/Dry Mode
About –5 to 52 °C
About –5 to 52 °C
About 18 to 30 °C
About 80 % or less
If the unit is used for long pe-
riods under high-humidity
conditions, condensation
may form on the surface of
the indoor unit, and drip onto
the floor or other objects un-
derneath.
AB 14TF
220-240 V~50 Hz
3.95-4.05
4.9-5.0
199
990
655
28
*Heating Mode
About –15 to 21 °C
About 16 to 30 °C or less
AB 18TF
AB 24TF
5.2-5.3
6.5-6.6
5.5-5.6
7.6-7.7
30