5.6.4 BBR16 power limitation

5.7 Setting up an external temperature sensor

EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G)
Daikin Altherma 3 H HT F
4P587502-1A – 2020.01
b
Full outdoor unit operation
c
Backup heater step 1 turned ON
INFORMATION
Restriction: BBR16 settings are only visible when the language of the user interface is
set to Swedish.
NOTICE
2 weeks to change. After you activated BBR16, you only have 2 weeks to change its
settings (BBR16 activation and BBR16 power limit). After 2 weeks, the unit
freezes these settings.
Note: This is different from the permanent power limitation, which is always
changeable.
Use the BBR16 power limitation when you must comply with BBR16 regulations
(Swedish energy regulations).
You can combine the BBR16 power limitation with the other power consumption
controls. If you do so, the unit uses the most restrictive control.
P
i
a
BBR16
P
Power input
i
t
Time
BBR16
BBR16 limit level
a
Power limitation active
b
Actual power input
Setup and configuration
No additional equipment needed.
Set the power consumption control settings in [9.9] via the user interface (see
"Power consumption
-
Activate BBR16
-
Set the desired power limitation level
You can connect one external temperature sensor. It measures the indoor or
outdoor ambient temperature. We recommend to use an external temperature
sensor in the following cases:
b
t
4
control" [
 184]):
5
Application guidelines
|
Installer reference guide
53