Dhw Pump For Tank Preheating; Setting Up The Energy Metering - Daikin EPRA16DAV3 Installer's Reference Manual

Hide thumbs Also See for EPRA16DAV3:
Table of Contents

5.4.6 DHW pump for tank preheating

5.5 Setting up the energy metering

EPRA14~18DAV3+W1 + ETBH/X16DF6V+9W
Daikin Altherma 3 H HT W
4P587501-1B – 2020.10
Setup
a
b
a DHW tank
b Cold water IN
c Hot water OUT (shower (field supply))
d Motorised 3‑way valve (field supply)
e DHW pump (field supply)
f Non‑return valve (field supply)
The DHW pump is field-supplied and its installation is the responsibility of the
installer. For the electrical wiring, see
4
pump" [
 109].
For the standalone DHW tank: If there is no electrical backup heater in the space
heating circuit, you must install a DHW pump for tank preheating.
Configuration
The indoor unit can control DHW pump operation. For more information, see
4
"9 Configuration" [
 116].
Via the user interface, you can read out the following energy data:
-
Produced heat
-
Consumed energy
You can read out the energy data:
-
For space heating
-
For space cooling
-
For domestic hot water production
You can read out the energy data:
-
Per month
-
Per year
f
e
d
M
"To connect the domestic hot water
5
Application guidelines
|
c
Installer reference guide
47