General error list

14.3
General error list
Table 12: General error list
Fault
Thermal shutdown
Low pressure warning
Accumulator
Malfunction or destruction
of electronic components
Vibrations at the axis
Axis does not move or
moves in an uncontrolled
manner or vibrates
Axis does not run smoothly Faults in the system
in the case of the message "Warning mark": It is still possible to operate the
1)
self-contained axis. Contact Bosch Rexroth Service.
in the case of the message "Shot-down mark": It is no longer possible to con-
tinue to operate the self-contained axis. Contact Bosch Rexroth Service.
Bosch Rexroth AG
Possible cause
Insufficient heat dissipation
The load cycle is outside the
specifications, e.g. pause time
was reduced or time in the force
control was extended
High external leakage in the
1)
system, leakage gas pressure
accumulator
Defective components, increased
noise development
Incorrect wiring
Too high vibration at the axis
Incorrect motor calibration
Wrong electronics installation and
wiring
Electrical signals are not received Check the electronics installation
Programming error in the soft-
ware / incorrect control of com-
ponents
Electro-hydraulic positioning ele-
ments do not switch
Wrong gas pressure in the
hydraulic accumulator
Remedy
Check whether mechanical engi-
neering parts or the installation sit-
uation allows as much convection
as possible
Deactivate cycle
Localize leakage
Observe the footnote
.
1)
Contact Bosch Rexroth Service.
Localize leakage
Contact Bosch Rexroth Service.
Check the wiring and the electrical
signals with the help of measuring
devices
Contact Bosch Rexroth Service.
Comply with the admissible vibra-
tion load
Contact Bosch Rexroth Service.
Check the settings.
Use the overview circuit diagrams
to check if installation and wiring
are correct
Contact Bosch Rexroth Service.
and wiring
Contact Bosch Rexroth Service.
Check the control of the electric
valves and motor and correct, if
necessary.
Check the electronics installation
and wiring.
Contact Bosch Rexroth Service.
Check gas pressure
Contact Bosch Rexroth Service.
Contact Bosch Rexroth Service.