Installation manual
R32 split series
ARXF50A5V1B
ARXF60A5V1B
ARXF71A5V1B
RXF50B5V1B
RXF60B5V1B
RXF71A5V1B
RXP50M5V1B
RXP60M5V1B
RXP71M5V1B
ARXM50R5V1B
ARXM60R5V1B
ARXM71R5V1B
RXM42R5V1B
Installation manual
RXM50R5V1B
English
R32 split series
RXM60R5V1B
Table of Contents
loading

Summary of Contents for Daikin ARXF50A5V1B

  • Page 1 Installation manual R32 split series ARXF50A5V1B ARXF60A5V1B ARXF71A5V1B RXF50B5V1B RXF60B5V1B RXF71A5V1B RXP50M5V1B RXP60M5V1B RXP71M5V1B ARXM50R5V1B ARXM60R5V1B ARXM71R5V1B RXM42R5V1B Installation manual RXM50R5V1B English R32 split series RXM60R5V1B...
  • Page 2 2P644862-1A...
  • Page 3 2P644862-1A...
  • Page 4: Table Of Contents

    Specifications of standard wiring components ......11 To connect the electrical wiring to the outdoor unit ....11 ▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required). 8 Finishing the outdoor unit installation To finish the outdoor unit installation.........
  • Page 5 2 Specific installer safety instructions Charging refrigerant (see "6 Charging refrigerant" [ 4  9]) WARNING The appliance shall be stored in a room without WARNING continuously operating ignition sources (example: open The refrigerant inside the unit is mildly flammable, but flames, an operating gas appliance or an operating electric normally does NOT leak.
  • Page 6: About The Box

    3 About the box WARNING About the box ALWAYS use multicore cable for power supply cables. Outdoor unit WARNING Use an all-pole disconnection type breaker with at least 3  mm between the contact point gaps that provide full 3.1.1 To remove the accessories from the disconnection under overvoltage category III.
  • Page 7: Additional Installation Site Requirements Of The Outdoor Unit In Cold Climates

    4 Unit installation NOTICE The height of the wall on the outlet side of the outdoor unit MUST be ≤1200 mm. Do NOT install the unit in sound sensitive areas (e.g. near a bedroom), so that the operation noise will cause no trouble. Note: If the sound is measured under actual installation conditions, the measured value might be higher than the sound pressure level mentioned in "Sound spectrum"...
  • Page 8: Piping Installation

    5 Piping installation Drain plug 5.1.2 Refrigerant piping insulation Hose (field supply) ▪ Use polyethylene foam as insulation material: To close the drain holes and attach the drain ▪ with a heat transfer rate between 0.041 and 0.052 W/mK (0.035 socket and 0.045 kcal/mh°C) NOTICE ▪...
  • Page 9: Checking The Refrigerant Piping

    6 Charging refrigerant CAUTION If the pressure… Then… Increases There is moisture in the ▪ Use the flare nut fixed to the unit. system. Go to the next step. ▪ To prevent gas leakage, apply refrigeration oil only to the inside of the flare. Use refrigeration oil for R32. 3 Vacuum the system for at least 2 hours to a manifold pressure of −0.1 MPa (−1 bar).
  • Page 10: To Determine The Additional Refrigerant Amount

    7 Electrical installation If a multilingual fluorinated greenhouse gases label is To determine the additional delivered with the unit (see accessories), peel off the refrigerant amount applicable language and stick it on top of a. Factory refrigerant charge: see unit name plate Additional refrigerant amount charged For ARXM71R Total refrigerant charge...
  • Page 11: Specifications Of Standard Wiring Components

    8 Finishing the outdoor unit installation 3 Open the wire clamp. DANGER: RISK OF ELECTROCUTION 4 Connect the interconnection cable and power supply as follows: Disconnect the power supply for more than 10  minutes, and measure the voltage at the terminals of main circuit capacitors or electrical components before servicing.
  • Page 12: Commissioning

    ▪ A subset of the latest technical data is available on the regional Daikin website (publicly accessible). To perform a test run ▪ The full set of latest technical data is available on the Daikin Business Portal (authentication required). Prerequisite: Power supply MUST be in the specified range.
  • Page 13: Unified Wiring Diagram Legend

    12 Technical data 12.1.1 Unified wiring diagram legend Symbol Meaning Coil For applied parts and numbering, refer to the wiring diagram on the Reactor unit. Part numbering is by Arabic numbers in ascending order for each part and is represented in the overview below by "*" in the part Stepper motor code.
  • Page 14: Piping Diagram

    12 Technical data 12.2 Piping diagram ▪ High pressure switch: category IV, 12.2.1 Piping diagram: Outdoor unit ▪ Compressor: category II; PED categories of equipment: ▪ Other equipment: art. 4§3. RXP50M, RXF50B, ARXF50A 7.0 CuT 4.0 CuT 7.0 CuT 6.4 CuT 6.4 CuT 7.0 CuT 7.0 CuT...
  • Page 15 12 Technical data RXP60M, RXP71M, RXF60B, RXF71A, ARXF60A, ARXF71A 7.0 CuT 7.0 CuT 4.0 CuT 7.0 CuT 7.0 CuT 6.4 CuT 6.4 CuT 4.0 CuT 7.0 CuT 7.0 CuT 4.0 CuT 12.7 CuT 12.7 CuT 12.7 CuT 6.4 CuT 6.4 CuT 9.5 CuT 12.7 CuT 12.7 CuT...
  • Page 16 12 Technical data ARXM71R 7.0 CuT 7.0 CuT 4.0 CuT 7.0 CuT 7.0 CuT 6.4 CuT 6.4 CuT 4.0 CuT 7.0 CuT 7.0 CuT 4.0 CuT 12.7 CuT 12.7 CuT 12.7 CuT 6.4 CuT 9.5 CuT 6.4 CuT 9.5 CuT 12.7 CuT 15.9 CuT Liquid field piping...
  • Page 17 12 Technical data RXM42R 7.0 CuT 7.0 CuT 4.0 CuT 7.0 CuT 7.0 CuT 6.4 CuT 4.0 CuT 6.4 CuT 7.0 CuT 7.0 CuT 4.0 CuT 12.7 CuT 12.7 CuT 12.7 CuT 6.4 CuT 6.4 CuT 9.5 CuT 9.5 CuT 9.5 CuT RXM50R, RXM60R, ARXM50R, ARXM60R 7.0 CuT...
  • Page 20 DAIKIN ISITMA VE SOĞUTMA SİSTEMLERİ SAN.TİC. A.Ş. Gülsuyu Mahallesi, Fevzi Çakmak Caddesi, Burçak Sokak, No:20, 34848 Maltepe İSTANBUL / TÜRKİYE Tel: 0216 453 27 00 Faks: 0216 671 06 00 Çağrı Merkezi: 444 999 0 Web: www.daikin.com.tr 3P645642-1A 2021.03 Verantwortung für Energie und Umwelt...