Verify Nvram - Dell Data Domain DD6300 Manual

Hide thumbs Also See for Data Domain DD6300:
Table of Contents

Verify NVRAM

Steps
1. Enter the enclosure show chassis command to check the battery and NVRAM chassis status.
NOTE:
The NVRAM battery might take up to 1.5 hours to get fully (100%) charged depending on how discharged the
NVRAM battery is at the time of the installation. However the filesystem is enabled when the battery capacity is above
80%, which should take a shorter time.
2. Enter the system show hardware command to check information about the NVRAM module.
3. Enter the system show nvram command to check battery and NVRAM status.
# system show
nvram
NVRAM Cards:
Card
Component
----
-----------------------
1
Slot
Firmware version
Memory size
Errors
Flash controller Errors
Board temperature
CPU temperature
Number of batteries
----
-----------------------
NVRAM Batteries:
Card
Battery
----
-------
1
1
----
-------
4. Enter the enclosure show misconfiguration command to verify if the NVRAM is in the correct slot.
# enclosure show misconfiguration
Memory DIMMs:
No misconfiguration found.
IO Cards:
No misconfiguration found.
CPUs:
No misconfiguration found.
Disks:
No misconfiguration found.
5. Run the alerts show current or alerts show current-detailed command to check alert information about
battery and NVRAM card status.
6. For HA systems that were failed over to the standby node before the component replacement, run the ha online
command on the standby node to bring the HA configuration back online.
Value
-----------------------------------------
0
0.0.78
7.93 GiB
0 memory (0 uncorrectable), 0 PCI, 0 controller
0 Cfg Err, 0 PANIC, 0 Bus Hang, 0 Bad Blk Warn,
39 C
48 C
1
-------------------------------------------
Status
Charge
Charging
Status
------
------
--------
ok
95 %
enabled
------
------
--------
0 Bkup Err, 0 Rstr Err
Time To
Full Charge
-----------
0 mins
----------- ----------- -------
Temperature Voltage
----------
-----
37 C
4.044 V
Field Replaceable Units
23

Hide quick links:

Table of Contents
loading

This manual is also suitable for:

Data domain dd6800Data domain dd9300