Connections To The Indoor Unit - Daikin Altherma 3 R ECH2O Installer's Reference Manual

Hide thumbs Also See for Altherma 3 R ECH2O:
Table of Contents
9
|
Electrical installation

9.3 Connections to the indoor unit

Installer reference guide
130
Connecting to the
frame
NOTICE
Precautions when making knockout holes:
Avoid damaging the casing and underlying piping.
After making the knockout holes, we recommend to remove the burrs and paint
the edges and areas around the edges using repair paint to prevent rusting.
When passing electrical wiring through the knockout holes, wrap the wiring with
protective tape to prevent damage.
7 Reattach the service cover. See
8 Connect an earth leakage circuit breaker and fuse to the power supply line.
Item
Power supply (main)
Power supply (backup
heater)
Backup heater
Shut-off valve
Electricity meters
Domestic hot water pump
Alarm output
When cables are routed from the unit, a protection
sleeve for the conduits (PG insertions) can be
inserted at the knockout hole.
When you do not use a wire conduit, protect the
wires with vinyl tubes to prevent the edge of the
knockout hole from cutting the wires.
A
B
a
c d
b
A Inside of the outdoor unit
B Outside of the outdoor unit
a Wire
b Bush
c Nut
d Frame
e Hose
"7.2.3 To close the outdoor
Description
See
"9.3.2 To connect the main power
4
supply" [
 135].
See
"9.3.3 To connect the backup heater power
4
supply" [
 137].
See
"9.3.4 To connect the backup heater to the main
4
unit" [
 140].
See
"9.3.5 To connect the shut-off
See
"9.3.6 To connect the electricity
See
"9.3.7 To connect the domestic hot water
4
pump" [
 143].
See
"9.3.8 To connect the alarm
ERLA11~16DAV3+W1 + EBSH/X(B)11+16P30+50DF
e
4
unit" [
 84].
4
valve" [
 141].
4
meters" [
 142].
4
output" [
 144].
Daikin Altherma 3 R ECH₂O
4P663482-1B – 2022.07