GE PACSystems RX3i IC695ETM001-JW Manual

GE PACSystems RX3i IC695ETM001-JW Manual

Ethernet interface module

Quick Links

GFK-2332Y
August 2017
The Ethernet Interface Module, IC695ETM001, connects a
PACSystems RX3i controller to an Ethernet network. It enables
the RX3i controller to communicate with other PACSystems
equipment and with Series 90 and VersaMax controllers. The
Ethernet Interface provides Transmission Control Protocol and
Internet Protocol (TCP/IP) communications with other control
systems, host computers running the Host Communications
Toolkit or programmer software, and computers running the
TCP/IP version of the programming software. These
communications use the Service Request Transport Protocol
(SRTP), Modbus TCP, and Ethernet Global Data (EGD) protocols
over a four-layer TCP/IP (Internet) stack.
Features of the RX3i Ethernet Interface include:
Full programming and configuration services. Firmware
upgrades from the RX3i CPU using the WinLoader
software utility, which is supplied with updates to the
Ethernet Interface software.
Periodic data exchange using Ethernet Global Data (EGD).
EGD Commands to read and write controller and EGD
exchange memory over the network.
TCP/IP communication services using SRTP.
Support for SRTP Channels, Modbus/TCP Server, and
Modbus/TCP Client
Built-in Station Manager for on-line supervisory access to
the Ethernet Interface. Dedicated Station Manager port.
Two auto-sensing 10Base T / 100Base TX RJ-45 shielded
twisted-pair Ethernet ports for direct connection to either
a 10BaseT or 100BaseTX IEEE 802.3 network without an external transceiver. There is only one interface to the
network (only one Ethernet MAC address and only one IP address).
Internal network switch with Auto negotiate, Sense, Speed, and crossover detection.
Recessed Ethernet Restart pushbutton permits manually restarting the Ethernet firmware without power cycling
the system.
LEDs: Ethernet OK, LAN OK, Log Empty, individual port activity and speed LEDs.
Configurable stand-alone Redundant IP addressing, which allows a single IP address to be assigned to
corresponding Ethernet modules in two different controllers. The Redundant IP address is configured in
addition to the normal unique IP address of each Ethernet module. Under application logic control, only the
Ethernet module in the active unit can use the Redundant IP address.
Time synchronization to SNTP Time Server on Ethernet network (when used with Release 5.00 or later CPU
module).
* Indicates a trademark of General Electric Company and/or its subsidiaries. All other trademarks are the property of their
respective owners.
Copyright © 2013- 2017 by General Electric Company. All Rights Reserved
PACSystems* RX3i
IC695ETM001-JW
Ethernet Interface Module
loading

Summary of Contents for GE PACSystems RX3i IC695ETM001-JW

  • Page 1 PACSystems* RX3i IC695ETM001-JW Ethernet Interface Module GFK-2332Y August 2017 The Ethernet Interface Module, IC695ETM001, connects a PACSystems RX3i controller to an Ethernet network. It enables the RX3i controller to communicate with other PACSystems equipment and with Series 90 and VersaMax controllers. The Ethernet Interface provides Transmission Control Protocol and Internet Protocol (TCP/IP) communications with other control systems, host computers running the Host Communications...
  • Page 2 RX3i Ethernet Interface Module IC695ETM001-HW IPI GFK-2332Y August 2017 IC695ETM001 Specifications Ethernet processor speed 200 MHz Connectors - Station Manager (RS-232) Port: 9-pin female D-connector - Two 10BaseT / 100BaseTX Ports: 8-pin female shielded RJ-45 IEEE 802.2 Logical Link Control Class I IEEE 802.3 CSMA/CD Medium Access Control 10/100 Mbps Number of IP addresses Number of Ethernet Port...
  • Page 3 RX3i Ethernet Interface Module IC695ETM001-HW IPI August 2017 GFK-2332Y Indicator Light Emitting Diodes (LEDs) State Indicates ETHERNET OK Fast Blink LAN OK Performing Diagnostics LOG EMPTY ETHERNET OK Slow Blink Waiting for Ethernet configuration LAN OK from CPU LOG EMPTY ETHERNET OK Slow Blink †...
  • Page 4: Hardware Installation

    The damaged shipping container should be saved as evidence for inspection by the carrier. As the consignee, it is your responsibility to register a claim with the carrier for damage incurred during shipment. GE Intelligent Platforms will fully cooperate with you, however, should such action be necessary.
  • Page 5: Module Installation

    RX3i Ethernet Interface Module IC695ETM001-HW IPI August 2017 GFK-2332Y Module Installation The ETM001 must be installed in the main (CPU) rack of an RX3i system, using a Universal Backplane such as IC695CHS007, CHS012 or CHS016. The ETM001 supports insertion/removal while power is applied to the system (hot swap).
  • Page 6 The IC695ETM001 is field upgradeable using the firmware upgrade utility. To upgrade an existing ETM001 to firmware version 6.41, you will need the upgrade kit 44A753032-G19, which can be downloaded from http://www.ge-ip.com/support. The hardware cannot be upgraded in the field.
  • Page 7: Release History

    Feb 2016 becoming unresponsive and requiring a power cycle if it was subjected to heavy network storm traffic. Reference: GE Security Advisory is GE15-09, titled Network Storm Denial of Service In addition to the enhancement there were issues resolved. Please refer to the “Problems Resolved by This Release”...
  • Page 8 RX3i Ethernet Interface Module IC695ETM001-HW IPI GFK-2332Y August 2017 Release History Firmware Catalog Number Version Date Comments IC695ETM001-FT 6.30 Oct. 2014 Firmware version 6.30 Fixes the following issues: • In very rare conditions closing Modbus or SRTP session can result in a 3-5 blink code. •...
  • Page 9 RX3i Ethernet Interface Module IC695ETM001-HW IPI August 2017 GFK-2332Y Release History Firmware Catalog Number Version Date Comments IC695ETM001-DG 5.50 May 2008 Adds ability to modify produced and consumed EGD exchanges during run mode store. For problems resolved, refer to GFK-2332F. IC695ETM001-DF 5.01 Dec.
  • Page 10 RX3i Ethernet Interface Module IC695ETM001-HW IPI GFK-2332Y August 2017 Restrictions and Open Issues Subject Description SRTP communication delays Average latency of communications on SRTP channels may vary considerably due to TCP retransmissions. SRTP client applications should be designed to take this variance into account. In particular, SRTP client applications migrating from Series 90 SRTP servers to PACSystems may need to lengthen SRTP timeout parameters.
  • Page 11 RX3i Ethernet Interface Module IC695ETM001-HW IPI August 2017 GFK-2332Y Restrictions and Open Issues Subject Description EGD command range failure When an EGD Command attempts a write operation to a bit-mode can write partial data to reference memory range (%I, %Q; %T, %M, %SA, %SB, %SC) where the controller bit memory amount of data to be written exceeds the configured size of that reference memory, the command will return failure status but partial data...
  • Page 12 RX3i Ethernet Interface Module IC695ETM001-HW IPI GFK-2332Y August 2017 Restrictions and Open Issues Subject Description COMMREQ Status Word value Occasionally a COMMREQ Status Word value of 0x54A0 is returned after of 0x54A0 occasionally COMMREQs for Ethernet Global Data commands when the previously- returned for EGD commands transferred command has experienced retries in the network.
  • Page 13 Appendix A, Configuring Advanced User Parameters in TCP/IP Ethernet Communications for PACSystems User’s Manual, GFK-2224K.) Changing the default Station GE Intelligent Platforms strongly recommends that you change the Station Manager password is strongly Manager password to a value other than the default. Before a...
  • Page 14 RX3i Ethernet Interface Module IC695ETM001-HW IPI GFK-2332Y August 2017 Ethernet Operational Notes Subject Description The Ethernet Interface cannot operate on a network until a valid IP Configuration of IP Address is address is configured. The Ethernet addressing information must be required before using Ethernet configured prior to actual network operation, or to recover from communications...
  • Page 15 RX3i Ethernet Interface Module IC695ETM001-HW IPI August 2017 GFK-2332Y Ethernet Operational Notes Subject Description Advanced User Parameter The Advanced User Parameter “wsnd_buf” should not be changed. wsnd_buf should not be Changing this value may cause the LAN LED to go out and the Ethernet changed Interface to drop connection.
  • Page 16: Additional Information

    PACSystems RX3i User Manuals GFK-2314 PACSystems RX3i System Manual TCP/IP Ethernet Communications for PACSystems GFK-2224 GFK-2225 PACSystems TCP/IP Communications, Station Manager Manual GE Automation & Controls Contact Information Americas: 1-800-433-2682 or 1-434-978-5100 Global regional phone numbers are available on our website www.geautomation.com...