XII.

PROGRAMMING WORKSHEETS

(Factory defaults for segments are in bold italics text and "Quick Start" locations are identified with the L symbol.)
LOC
PG
L
0
13
PHONE #1
L
1
13
PHONE #1, ACCOUNT CODE
L
2
13
PHONE #1, REPORTING FORMAT
L
3
13
PHONE #1, DIAL ATTEMPTS
BACKUP CONTROL
4
14
PHONE #1, SELECTING EVENTS TO REPORT TO PHONE #1
Segment #1 (Circle Numbers To Program)
1 = Alarms and Restores
2 = Open/Close
3 = Bypass
4 = Zone Trouble
5 = Power Trouble (AC Failure or Low Battery)
6 = Siren & Telephone Fault
7 = Test Reports
8 = Program, Download, & Log Full
5
14
PHONE #1, SELECTING WHICH PARTITIONS REPORT TO PHONE #1
Segment #1
1 = Partition #1
2 = Partition #2
L
6
14
PHONE #2
L
7
14
PHONE #2, ACCOUNT CODE
L
8
15
PHONE #2, REPORTING FORMAT
9
15
PHONE #2, DIAL ATTEMPTS
BACKUP CONTROL
10
15
PHONE #2, SELECTING EVENTS TO REPORT TO PHONE #2
Segment #1 (Circle Numbers To Program)
1 = Alarms and Restores
2 = Open/Close
3 = Bypass
4 = Zone Trouble
5 = Power Trouble (AC Failure or Low Battery)
6 = Siren & Telephone Fault
7 = Test Reports
8 = Program, Download, & Log Full
11
16
PHONE #2, SELECTING WHICH PARTITIONS REPORT TO PHONE #2
Segment #1
1 = Partition #1
2 = Partition #2
12
16
PHONE #3
13
16
PHONE #3, ACCOUNT CODE
NX-8E CONTROL
DESCRIPTION
(Circle Numbers To Program)
3 = Partition #3
4 = Partition #4
(Circle Numbers To Program)
3 = Partition #3
4 = Partition #4
DEFAULT
14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-
14-14
10 - 10 - 10 - 10 - 10 - 10
0
8
0
Segment #2 (Circle Numbers To Program)
1 = Tampers
2 = Short Circuit & Ground Fault
3 = Sensor Lost
4 = Sensor Low Battery
5 = Expander Trouble
6 = Failure To Communicate
7 = Zone Activity Monitor
8 = Reserved
5 = Partition #5
6 = Partition #6
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
10 - 10 - 10 - 10 - 10 - 10
0
8
0
Segment #2 (Circle Numbers To Program)
1 = Tampers
2 = Short Circuit & Ground Fault
3 = Sensor Lost
4 = Sensor Low Battery
5 = Expander Trouble
6 = Failure To Communicate
7 = Zone Activity Monitor
8 = Reserved
5 = Partition #5
6 = Partition #6
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
10 - 10 - 10 - 10 - 10 - 10
PROGRAMMING DATA
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
_ _ _ _ _ _
_
_
_
7 = Partition #7
8 = Partition #8
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
_ _ _ _ _ _
_
_
_
7 = Partition #7
8 = Partition #8
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
_ _ _ _ _ _
45
Table of Contents
loading

This manual is also suitable for:

Nx-8e

Table of Contents