Maintenance; Troubleshooting - Emerson BUILDER UNIPACK CF701ORB00 Owner's Manual

Hide thumbs Also See for BUILDER UNIPACK CF701ORB00:
Table of Contents

Maintenance

IMPORTANT CARE INSTRUCTIONS
for your Ceiling Fan
Periodic cleaning of your new ceiling fan is the only
maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth
to avoid scratching the finish.
Abrasive cleaning agents are not required and should
be avoided to prevent damage to finish.
WARNING
!
Do not use water when cleaning your ceiling fan. It
could damage the motor or the blades and create the
possibility of an electrical shock.
!
WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble
shooting your fan.
TROUBLE
1. Fan will not start.
2. Fan sounds noisy.
3. Fan wobbles
excessively.
Trouble Shooting
PROBABLE CAUSE
1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan, or loose
switch wire connections in the switch housing.
3. Reversing switch in neutral position.
1. Blades not attached to fan.
2. Screws securing fan blade flanges to motor hub
are loose.
3. Wire connectors inside switch housing rattling.
4. Motor noise caused by solid-state variable
speed control.
5. Screws holding blades to flanges are loose.
1. Setscrews in motor coupling are loose.
2. Setscrew in hanger ball/downrod assembly is
loose.
3. Screws securing fan blade flanges to motor are
loose.
4. Fan blade flanges not seated properly.
5. Hanger bracket and/or ceiling outlet box is not
securely fastened.
6. Fan blades out of balance.
Accessories
1. Ceiling Fan/Light Controls (see store or catalog).
2. Downrod Extension Kits (see store or catalog).
!
The use of any other control not specifically
approved for this fan could result in fire, shock and
personal injury.
!
This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Company. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Company could result in
personal injury or property damage.
1. Check main and branch circuit fuses or circuit breakers.
WARNING: Make sure main power is turned off.
!
2. Check line wire connections to fan and switch wire
connections in the switch housing.
3. Make sure reversing switch position is all the way to one
side.
1. Attach blades to fan before operating.
2. Check to make sure the screws which attach the fan
flanges to the motor hub are tight.
WARNING: Make sure main power is turned off.
!
3. Check to make sure wire connectors in switch housing
are not rattling against each other or against the interior
wall of the switch housing.
4. Some fan motors are sensitive to signals from Solid-
State variable speed controls. If Solid-State Control
is used and motor noise results choose an alternative
control method.
5. Tighten screws securely.
1. Tighten both setscrews securely in the motor coupling.
2. Tighten the setscrew in the hanger ball/downrod
assembly.
3. Check to be sure screws which attach the fan blade
flanges to the motor are tight.
4. Check to be sure the fan blade flanges seat firmly and
uniformly to the surface of the motor.
5. Tighten the hanger bracket screws to the outlet box,
and/or secure outlet box.
6. Interchanging an adjacent (side-by-side) blade pair can
redistribute the weight and result in smoother operation.
9
WARNING
WARNING
SUGGESTED REMEDY
U.L. Model No.: CF701
Table of Contents
loading