About The Box; Outdoor Unit; To Remove The Accessories From The Outdoor Unit; Unit Installation - Daikin Altherma 3 M Installation Manual

Hide thumbs Also See for Altherma 3 M:
Table of Contents

3 About the box

CAUTION
Do NOT push or place redundant cable length in the unit.
WARNING
The backup heater MUST have a dedicated power supply
and MUST be protected by the safety devices required by
the applicable legislation.
CAUTION
To guarantee the unit is completely earthed, ALWAYS
connect the backup heater power supply and the earth
cable.
WARNING
Stripped wire. Make sure that stripped wire cannot make
contact with possible water on the bottom plate.
Commissioning (see "9 Commissioning" [ 4  40])
WARNING
Commissioning method MUST be in accordance with the
instructions
from
"9 Commissioning" [ 4  40].
3
About the box
3.1

Outdoor unit

3.1.1
To remove the accessories from the
outdoor unit
1 Remove the accessories on top and in front of the unit.
a
b
c
a
Installation manual vibration dampers
b
General safety precautions
c
Operation manual
d
Installation manual
e
Addendum book for optional equipment
f
Energy label
g
WLAN cartridge
h
User interface (front plate, rear plate, screws, and wall
plugs)
i
Unit mounting plate
j
Vibration dampers
k
Cable tie
l
Bolts, nuts, washers, and spring washers
Installation manual
8
this
manual.
See
d
e
f
g
h
i
j
k
l
2 After opening the unit (see
unit" [ 4  11]), remove the accessory inside the unit.
m
m
Shutoff valve
4

Unit installation

4.1

Preparing the installation site

WARNING
The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating ignition sources (example: open flames, an
operating gas appliance or an operating electric heater).
4.1.1
Installation site requirements of the
outdoor unit
Mind the following spacing guidelines:
b
>
30
0
a
≥500
(mm)
>
30
0
>350
b
a
(mm)
a
Air outlet
b
Air inlet
The outdoor unit is designed for outdoor installation only, and for the
following ambient temperatures:
Cooling mode
10~43°C
Heating mode
–25~25°C
DHW production
–25~35°C
Mind the measurement guidelines:
Maximum height difference between domestic hot
water tank and outdoor unit
Maximum distance between outdoor unit and...
domestic hot water tank
3-way valve
external backup heater kit
EBLA04~08E2V3+E23V3 + EDLA04~08E2V3+E23V3
"4.3.1  To open the outdoor
b
>
30
0
a
>250
(mm)
5 m
10 m
(a), (b)
(25 m
10 m
(a), (b)
(25 m
10 m
Daikin Altherma 3 M
4P685229-1A – 2022.05
)
)
Table of Contents
loading