Table Of Contents; About This Document - Daikin Altherma 3 M Installation Manual

Hide thumbs Also See for Altherma 3 M:
Table of Contents

Table of contents

Table of contents
3.1
Outdoor unit...............................................................................
3.1.1
4.1
Preparing the installation site ....................................................
4.1.1
4.1.2
outdoor unit in cold climates .......................................
4.2
Mounting the outdoor unit..........................................................
4.2.1
To provide the installation structure ............................
4.2.2
To install the outdoor unit............................................ 10
4.2.3
To provide drainage .................................................... 10
4.2.4
4.3
Opening and closing the unit..................................................... 11
4.3.1
To open the outdoor unit............................................. 11
4.3.2
To rotate the switch box.............................................. 11
4.3.3
To close the outdoor unit ............................................ 11
5.1
Preparing water piping .............................................................. 12
5.1.1
5.1.2
Third-party tank requirements..................................... 13
5.2
Connecting water piping............................................................ 13
5.2.1
To connect the water piping........................................ 13
5.2.2
To fill the water circuit ................................................. 13
5.2.3
5.2.4
To fill the domestic hot water tank .............................. 14
5.2.5
To insulate the water piping ........................................ 14
6.1
About electrical compliance....................................................... 15
6.2
6.3
Connections to the outdoor unit ................................................ 15
6.3.1
6.3.2
To connect the main power supply ............................. 17
6.3.3
6.3.4
External backup heater kit .......................................... 20
6.3.5
To connect the user interface ..................................... 22
6.3.6
To connect the shut-off valve...................................... 24
6.3.7
To connect the electricity meters ................................ 25
6.3.8
6.3.9
To connect the alarm output ....................................... 25
6.3.10
output .......................................................................... 26
6.3.11
6.3.12
6.3.13
contact) ....................................................................... 27
6.3.14
To connect a Smart Grid............................................. 27
7.1
8.1
Overview: Configuration ............................................................ 29
8.1.1
To access the most used commands ......................... 30
8.2
Configuration wizard.................................................................. 31
8.2.1
Configuration wizard: Language ................................. 31
8.2.2
Configuration wizard: Time and date .......................... 31
8.2.3
Configuration wizard: System ..................................... 31
8.2.4
Configuration wizard: Backup heater .......................... 33
8.2.5
Configuration wizard: Main zone................................. 33
8.2.6
Configuration wizard: Additional zone......................... 34
Installation manual
6
8.2.7
Configuration wizard: Tank .......................................... 34
8.3
Weather-dependent curve.......................................................... 35
8.3.1
What is a weather-dependent curve? .......................... 35
8.3.2
2-points curve .............................................................. 36
6
8.3.3
Slope-offset curve ........................................................ 36
8.3.4
Using weather-dependent curves ................................ 37
7
8.4
Settings menu ............................................................................ 37
8.4.1
Main zone .................................................................... 37
8
8.4.2
Additional zone ............................................................ 38
8
8.4.3
Information ................................................................... 38
8
8.5
Menu structure: Overview installer settings................................ 39
8
8
9.1
Checklist before commissioning................................................. 40
8
9.2
Checklist during commissioning ................................................. 40
9.2.1
To check the minimum flow rate .................................. 40
9
9.2.2
To perform an air purge ............................................... 41
9
9.2.3
To perform an operation test run ................................. 41
9
9.2.4
To perform an actuator test run ................................... 41
9.2.5
11.1
Piping diagram: Outdoor unit...................................................... 43
11.2
Wiring diagram: Outdoor unit ..................................................... 45
12
1

About this document

Target audience
Authorised installers
Documentation set
This document is part of a documentation set. The complete set
consists of:
▪ General safety precautions:
15
▪ Safety instructions that you must read before installing
▪ Format: Paper (in the box of the outdoor unit)
▪ Operation manual:
▪ Quick guide for basic usage
▪ Format: Paper (in the box of the outdoor unit)
▪ User reference guide:
▪ Detailed step-by-step instructions and background information
for basic and advanced usage
▪ Format: Digital files on
and-manuals/product-information/
▪ Installation manual:
▪ Installation instructions
▪ Format: Paper (in the box of the outdoor unit)
▪ Installer reference guide:
▪ Preparation of the installation, good practices, reference
data, ...
29
▪ Format: Digital files on
and-manuals/product-information/
29
▪ Addendum book for optional equipment:
▪ Additional info about how to install optional equipment
▪ Format: Paper (in the box of the outdoor unit) + Digital files on
http://www.daikineurope.com/support-and-manuals/product-
information/
Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.
EBLA04~08E2V3+E23V3 + EDLA04~08E2V3+E23V3
http://www.daikineurope.com/support-
http://www.daikineurope.com/support-
Daikin Altherma 3 M
4P685229-1A - 2022.05
40
42
43
Table of Contents
loading

Table of Contents