Mitsubishi Electric LAN UNIT Technical Manual

Industrial sewing machine

Quick Links

INDUSTRIAL SEWING MACHINE
LAN UNIT
MODEL
PLK-J-LAN
TECHNICAL MANUAL
A180E806P02
Table of Contents
loading

Summary of Contents for Mitsubishi Electric LAN UNIT

  • Page 1 INDUSTRIAL SEWING MACHINE LAN UNIT MODEL PLK-J-LAN TECHNICAL MANUAL A180E806P02...
  • Page 2: Table Of Contents

    contents [1] For safe use __________________________________________________ [2] Precautions for use ____________________________________________ [3] Use __________________________________________________________ [4] Name of each part _____________________________________________ [5] Pin number of connectors _______________________________________ [6] External dimensions ___________________________________________ 7 [7] Connection method ____________________________________________ 7 1. How to connect XC-G .................... 8 2.
  • Page 3 * The contents of this manual are subject to change without notice. * An utmost effort has been made to cover all points of operation in this manual. Contact Mitsubishi if you have any questions regarding the contents. COPYRIGHT(C)2019 MITSUBISHI ELECTRIC CORPORATION...
  • Page 4: For Safe Use

    [1] For safe use For safe use Always observe the following matters to safely use this product. Before starting Before using this product, read all of the technical manuals carefully, and correctly use the unit following the manual. Also read the instruction manual of the sewing machine to be installed. Application and purpose This product is designed as a communication device of the Mitsubishi industrial sewing machine.
  • Page 5: Precautions For Use

    [2] Precautions for use 1. Do not inspect the control circuit with a tester. The tester voltage could be applied on the semiconductor parts, and cause damage. 2. Always align the connector shape and direction, and securely insert the connector. 3.
  • Page 6: Use

    It acquires the information such as sewing time from the sewing machine and performs Ethernet communication with the master station as slave station. Required network device Equipment of the master station: Mitsubishi Electric PLC (MELSEC iQ-F、iQ-R series) Equipment for display: PC, Mitsubishi Electric Visualization etc. Other equipment: HUB etc.
  • Page 7: Name Of Each Part

    [4] Name of each part 1. Front side 2. Back side Name Function LED (green) POWER LED LED (red) Warning LED CON A (USB-Mini B connector) Do not use Connect the control switch panel (XC-G10 / XC-G500). CON B (MINI-DIN connector) Please do not use when connecting with PLK-G series.
  • Page 8: Pin Number Of Connectors

    [5] Pin number of connectors 1. CON C CON C (General purpose input / output connector) signal Pin number Used connector : TE Connectivity 172161-1 Used terminal : TE Connectivity 170362-1 2. Ratings value of input /output (1) Output (open collector) Output Connector pin Ratings current...
  • Page 9 (3) Analog output Output Connector pin Power Output voltage Maximum ratings current CON C 9PIN DC12V DC 0~10V 0.01A less * Use the input resistance of the connection destination at 1k or more Example of use Input devise * Output total 0.1A or less Power DC12V PLK-J-...
  • Page 10: External Dimensions

    [6] External dimensions 4.5 ㎜ 125.3 ㎜ 40 ㎜ [7] Connection method CON B Front Control switch panel side XC-G10 / XC-G500 Back side CON E Network device RS232C cable XC-G control box PLK-G control box...
  • Page 11: How To Connect Xc-G

    How to connect XC-G Control switch panel XC-G Control XC-G500 XC-G10 Control switch RS232C cable panel Cable PLK-J-LAN 前面 PLK-J-LAN front side PLK-J-LAN back side LAN cable LAN cable How to connect PLK-G * Connect the RS233C cable of PLK-J-LAN to the front panel of the control box. RS232C cable PLK-J-LAN back side LAN cable...
  • Page 12: Update And Setting

    [8] Update and setting In order to use PLK-J-LAN, update LAN system data as needed and set IP address etc. using USB flash drive. * When setting only the IP address etc. please put the setting data in the USB flash drive. (LAN system data is unnecessary.) What the user needs to prepare ・Please create a folder of "MAKER"...
  • Page 13: How To Use

    [9] How to use It is a communication device enabling network communication for XC-G and PLK-G series. By connecting using PLK-J-LAN, you can collect data of the sewing machine and so on. XC-G (Initial setting) 1. Connect the wiring before turning on the power. ・Connect the RS232C cable of PLK-J-LAN to the MINI-DIN connector on the front of the XC-G.
  • Page 14: Confirmation

    [10] Confirmation 1. Before turning the switch on (1) Are the cable correctly inserted ? ・Cable for connection with sewing machine. ・Cable for connection with HUB. ・Cable for connection with control switch panel. 2. After turning switch on (1) Is the front panel power LED (green) on ? (2) Is the front panel warning LED (red) on or flickering ? (3) Is there an heating, odors or abnormal noise from PLK-J-LAN, the motor or control box ? Turn the sewing machine off and contact your dealer...
  • Page 15: Error Indication

    [11] Error indication When an error occurs, the error display LED (red) on the front panel blinks. Please deal with the reference below. PLK-J-LAN front panel error display LED (red) is blinking [ Red LED ] Blink pattern : ON : OFF - - - - - -...
  • Page 16: Specification

    [12] Specification Basic specifications MITSUBISHI LIMI Servo Mitsubishi electronic pattern sewing access point XC-G series PLK-G series machine XC-G series control box PLK-G series control box Connected equipment Control switch panel (System ver.S100W018 or later) DC12V DC12V power supply (Supplied from the control box) (Supplied from the control box) Ethernet communication (1 port) Communication interface...
  • Page 20 MITSUBISHI ELECTRIC CORPORATION Printed in Japan...