Page 2
Installation diagram type SAL95AHC Saladette “950“ with chopping-boarding...
Page 3
Installation diagram type SAL95BHC Saladette “950“ Pizza...
Page 4
Installation diagram type SAL95DHC Saladette “950“ with steel top...
Page 5
Installation diagram type SAL95CHC Saladette “950“ without top...
Page 6
EI = Power cable length B = version Pizza TYPE = Certification group C = version with steel top SAL95 = Saladette 950 range D = version without top A = version with chopping-boarding HC = R290 refrigerant...
Page 7
Foreword Read the following instructions, including the warranty terms before installing and using the appliance. Visit our website www.electroluxprofessional.com and open the Support section to: Register your product Get hints & tips of your product, service and repair information The installation, use and maintenance manual (hereinafter Manual) provides the user with information necessary for correct and safe use of the appliance.
Contents A WARNING AND SAFETY INFORMATION....................10 General information ........................10 Personal protection equipment ...................... 10 General safety ........................... 11 Protection devices installed on the appliance ..................11 Safety signs to be placed on the appliance or near its area ..............11 Reasonably foreseeable improper use ....................
Page 9
K MACHINE CLEANING AND MAINTENANCE..................... 21 Ordinary maintenance ......................... 21 K.1.1 Care information ....................... 21 K.1.2 Cleaning the cabinet and accessories..................22 K.1.3 Precautions in case of long idle periods ................. 22 L MACHINE DISPOSAL........................... 22 Introduction ..........................22 Waste storage..........................22 Procedure regarding appliance dismantling macro operations ..............
WARNING AND SAFETY INFORMATION General information To ensure safe use of the appliance and a proper understanding of the manual it is necessary to be familiar with the terms and typographical conventions used in the documentation. The following symbols are used in the manual to indicate and identify the various types of hazards: WARNING Danger for the health and safety of operators.
Stage Protective Safety footwear Gloves Glasses Safety helmet garments Key: ● PPE REQUIRED ○ PPE AVAILABLE OR TO BE USED IF NECESSARY — PPE NOT REQUIRED During these operations, gloves must be cut-resistant. Failure to use the personal protection equipment by operators, specialized personnel or users can involve exposure to damage to health (depending on the model).
Danger Meaning caution hot surface danger of electrocution (shown on electrical parts with indication of voltage) Reasonably foreseeable improper use Improper use is any use different from that specified in this manual. During appliance operation, other types of work or activities deemed improper and that in general can involve risks for the safety of operators and damage to the appliance are not allowed.
Technical data • The data plate and the energy labelling refer to original manufactured configuration. • The appliance that can operate at 50 Hz or 60 Hz does not need any setting by the user. Materials and fluids used • R290 gas is potentially flammable and explosive. Take every possible precaution to prevent any risk linked to the nature of this gas during any routine and/or extraordinary operation carried out on the appliance.
A.14 Electrical connection for appliances with cable without plug • The connection point has an efficient earth contact and the mains voltage and frequency match that given on the data plate. In case of doubts regarding the efficiency of the earth wire, have the system checked by specialised personnel. •...
A.22 Preventive Maintenance In order to ensure the safety and performance of your equipment, it is recommended that service is undertaken by Electrolux Professional authorised engineers every 12 months, in accordance with Electrolux Professional Service Manuals. Please contact your local Electrolux Professional Service Centre for further details.
Illuminazione / Lighting Cap. power input IPxx absorbed current Electrolux Professional SPA - Viale Treviso, 15 - 33170 Pordenone (Italy) Evaporation evaporation heating element power The meaning of the various information given on it is listed heater El. below:...
The drawings and diagrams given in the manual are not in Manufacturer Electrolux Professional SpA or any other scale. They supplement the written information with an outline, service centre authorised by Electrolux but are not intended to be a detailed representation of the Professional SpA.
• non-application of the current provisions in the country of personal protection equipment to be worn by operators, in use, concerning safety, hygiene and health in the workplace. compliance with regulations in force in the country of use. The Manufacturer declines any liability for damage caused by The Manufacturer declines any liability for inaccuracies con- arbitrary modifications and conversions carried out by the user tained in the manual, if due to printing or translation errors.
Storage Polyethylene The machine and/or its parts must be stored and protected • Outer wrapping from damp, in a non-aggressive place, free of vibrations and • Instructions bag with room temperatures between 5℃ and 50℃. The place where the machine is stored must have a flat Polypropylene support surface to avoid deforming the machine or damage to the support feet.
Models with steel top Ø 3 mm CONTROL PANEL Description of control panel Auxiliary users on signalling icon Defrost cycle activated signalling icon Compartment fans on signalling icon Compressor on signalling icon Temperature alarm signalling icon “Prg/mute“ button for silencing the alarm buzzer. Multifunction ON/OFF and UP button for switch- ing the appliance on and off and for increasing the values.
Alarms and signalling Product loading I.3.1 Service alarms and signalling for models 0 ℃/+10 Distribute the product evenly inside the compartment (away ℃ from the door and back) in order to allow good air circulation. The alarm is signalled by lighting up of the icon .
Page 22
IMPORTANT CAUTION Problems resulting from poor or lack of care as Do not use products (even if diluted) hereinafter described will not be covered by the containing chlorine (sodium hypochlorite, warranty. hydrochloric or muriatic acid, etc.) to clean WARNING the floor under the appliance. Before carrying out any cleaning or maintenance, disconnect the appliance from the power supply.
Page 23
TROUBLESHOOTING In some cases, faults can be eliminated easily and quickly by following a brief troubleshooting guide: TYPE OF ANOMALY DESCRIPTION POSSIBLE CAUSES ACTIONS ANOMALY • Connector unplugged Compartment ALARM CALL SERVICE • Probe and/or Probe wire sensor fault damaged •...