Frame Shape And Installation Position; General - Bosch Rexroth MAD Project Planning Manual

Asynchronous housing motors
Hide thumbs Also See for Rexroth MAD:
Table of Contents
MAD / MAF Asynchronous Housing Motors
9.6

Frame shape and Installation position

9.6.1

General

MAD/MAF motors are available in frame shapes B05 and B35. The installa‐
tion types allowed according to EN 60034-7 are shown in the following table.
Motor
Allowed installation types
Frame
shape
Designation
IM B5
IM V1
B05
IM V3
IM B3
B35
IM B5
Tab. 9-5:
Mounting position
MAD/MAF motors of frame shape B35 can be attached either via foot or
flange mounting.
Drawing
Installation
Flange mounting on the drive side of
the flange
Flange mounting on the drive side of
the flange, drive side facing down
Flange mounting on the drive side of
the flange, drive side facing up
Foot assembly, feet at the bottom
Flange mounting on the drive side of
the flange
R911295781_Edition 11 Bosch Rexroth AG
193/265