Connection Diagram - Bosch Rexroth MAD Project Planning Manual

Asynchronous housing motors
Hide thumbs Also See for Rexroth MAD:
Table of Contents
MAD / MAF Asynchronous Housing Motors
8.4.3

Connection diagram

A1
A2
A3
4
+24VBr
0VBr
MotTemp+
MotTemp-
Holding brake (option)
Spare temperature sensor (connect spare sensor lines only if
necessary)
Shield connection by clamping the cables of the strain relief in
the cable gland
Connection designations on the Rexroth drive controller
Fig. 8-3:
Terminal box connection diagram
Brake connections 1-2 are only assigned if the motor is man‐
ufactured with the optional brake.
Only one contact pair of PTC thermistor connections 3-4 and
5-6 is connected to the motor cable.
The seal which is glued into the lid at the factory may not de‐
tached or damaged.
Observe the size of the cable gland and connection thread
for the cable inlet into the terminal box.
Make particularly sure that the connecting cables are placed
orderly and without strain in the terminal box to prevent rub‐
bing or pressure marks on the cables.
The connections of the motor windings in the terminal box
may not be removed.
Connection techniques
1
2
3
GNYE
BD (+)
7
1
8
BD (-)
2
5
1TP1 (+)
3
1TP2 (-)
6
4
5
6
3
R911295781_Edition 11 Bosch Rexroth AG
177/265
U
M
V
3
W
1
1
2
3
4
(+)
5
(-)
6
2