MAD / MAF Asynchronous Housing Motors
8.4.3
Connection diagram
A1
A2
A3
4
+24VBr
0VBr
MotTemp+
MotTemp-
①
Holding brake (option)
②
Spare temperature sensor (connect spare sensor lines only if
necessary)
③
Shield connection by clamping the cables of the strain relief in
the cable gland
④
Connection designations on the Rexroth drive controller
Fig. 8-3:
Terminal box connection diagram
●
Brake connections 1-2 are only assigned if the motor is man‐
ufactured with the optional brake.
●
Only one contact pair of PTC thermistor connections 3-4 and
5-6 is connected to the motor cable.
●
The seal which is glued into the lid at the factory may not de‐
tached or damaged.
●
Observe the size of the cable gland and connection thread
for the cable inlet into the terminal box.
●
Make particularly sure that the connecting cables are placed
orderly and without strain in the terminal box to prevent rub‐
bing or pressure marks on the cables.
●
The connections of the motor windings in the terminal box
may not be removed.
Connection techniques
1
2
3
GNYE
BD (+)
7
1
8
BD (-)
2
5
1TP1 (+)
3
1TP2 (-)
6
4
5
6
3
R911295781_Edition 11 Bosch Rexroth AG
177/265
U
M
V
3
W
1
1
2
3
4
(+)
5
(-)
6
2