Warranty - Panasonic Secon H Series Installation And Setup

Monobloc system
Table of Contents
Please check the following before commencing startup as they are important conditions of
Panasonics warranty.
A magnetic filter must be installed in the return pipe as close as possible to the unit. Do
not switch the system on without this.
A buffer tank or low loss header must be used to create hydraulic separation and ensure
a minimum primary water volume of either 30 litres (single fan unit) or 50 litres (twin
fan unit). If using a low loss header then a volumising tank is probably required.
The pipe diameter used must be no smaller than 28mm copper (larger if plastic)
If glycol (anti-freeze) is used then this should be food safe and pre mixed before intro-
duction and of the correct strength for the system. Most applications will require this.
The water quality should be tested against Panasonics requirements.
Part of the startup process involves checking the water flow rate. In order for the unit to op-
erate at all then an absolute minimum low rates must be observed aswell as the
recommended pipework sizing.
*Please note that these sizes are for guidance only and may differ dependant on pipe run, pressure losses within the system and
number of bends.
A full copy of Panasonics Warranty Terms and Conditions can be found at
https://www.aircon.panasonic.eu/GB_en/downloads/others/
T: 0191 516 6554

Warranty

kW output of unit
5
Flow rate (L/min)
14.3
Primary Pipework sizing Guide
kW Output
5kW
7kW
9kW
12kW
16kW
W: www.seconrenewables.com
7
9
12
20.1
25.8
34.4
Copper Pipe Size O/D (mm)*
22
22
28
28
35
16
45.9