DISPOSAL OF OUTDOOR UNIT DRAIN WATER
When a Drain elbow
1
- the unit should be placed on a stand which is taller than 50 mm.
- cover the ø20mm holes with Rubber cap
- use a tray (fi eld supply) when necessary to dispose the outdoor unit drain water.
If the unit is used in an area where temperature falls below 0°C for 2 or 3 consecutive days, it is recommended not to use the Drain elbow 1
and Rubber cap 2 , for the drain water freezes and the fan will not rotate.
2
Rubber cap
WH-UD03JE5* and WH-UD05JE5*

CONNECTING THE PIPING

3
CONNECTING THE PIPING TO OUTDOOR UNIT
Decide piping length and then cut by using pipe cutter. Remove burrs
from cut edge. Make fl are after inserting the fl are nut (locate at valve)
onto the copper pipe. Align center of piping to valves and then tighten
with torque wrench to the specifi ed torque as stated in the table.
Model
WH-UD03JE5* and
WH-UD05JE5*
WH-UD07JE5* and
WH-UD09JE5*
Please cut using pipe cutter and then remove the burrs.
1.
Remove the burrs by using reamer. If burrs is not removed, gas leakage may be caused.
2.
Turn the piping end down to avoid the metal powder entering the pipe.
3.
Please make fl are after inserting the fl are nut onto the copper pipes.
Point down
1. To cut
2. To remove burrs
8
is used, please ensure to follow below:
2
(refer to illustration below).
Drain elbow
x 7
Piping size (Torque)
Gas
Liquid
ø12.7mm (1/2")
ø6.35mm (1/4")
[55 N•m]
[18 N•m]
ø15.88mm (5/8")
ø6.35mm (1/4")
[65 N•m]
[18 N•m]
CUTTING AND FLARING THE PIPING
Pipe
Reamer
Bar
Clamp handle
3. To fl are
1
Rubber cap
WH-UD07JE5* and WH-UD09JE5*
Spanner or
Wrench
Be sure to use two spanners to tighten.
(If the nuts are overtightened, it may cause the fl ares to break or leak.)
Handle
0 – 0.5 mm
Bar
Yoke
Core
Copper pipe
Red arrow mark
Drain elbow
2
x 3
Torque
wrench
 Improper fl aring 
Inclined Surface
Cracked Uneven
damaged
When properly fl ared, the internal surface of the
fl are will evenly shine and be of even thickness.
Since the fl are part comes into contact with the
connections, carefully check the fl are fi nish.