Vaillant auroSTOR Installation And Maintenance Instructions Manual

Vaillant auroSTOR Installation And Maintenance Instructions Manual

Hide thumbs Also See for auroSTOR:

Quick Links

Installation and maintenance instructions
Publisher/manufacturer
Vaillant GmbH
Berghauser Str. 40
D-42859 Remscheid
Tel. +492191 18 0
Fax +492191 18 2810
www.vaillant.de
auroSTOR
VIH S GB .../3 BES
GB, IE
Table of Contents
loading

Summary of Contents for Vaillant auroSTOR

  • Page 1 Installation and maintenance instructions auroSTOR VIH S GB .../3 BES GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Tel. +492191 18 0 Fax +492191 18 2810 [email protected] www.vaillant.de...
  • Page 2: Table Of Contents

    Checking the pre-charge pressure of the expansion vessel ..........15 Decommissioning the product ......15 Customer service..........15 Appendix ................16 Detecting and eliminating faults ...... 16 Inspection and maintenance work – Overview............. 16 Installation and maintenance instructions auroSTOR 0020221298_04...
  • Page 3: Safety 1

    ▶ Only carry out work on these components once they have cooled down. Intended use includes the following: – observance of accompanying operating, installation and maintenance instructions 0020221298_04 auroSTOR Installation and maintenance instructions...
  • Page 4: Regulations (Directives, Laws, Standards)

    1.4.6 Risk of injury due to the heavy weight of the product ▶ Make sure that the product is transported by at least two people. Regulations (directives, laws, standards) ▶ Observe the national regulations, stand- ards, directives, ordinances and laws. Installation and maintenance instructions auroSTOR 0020221298_04...
  • Page 5: Notes On The Documentation 2

    VIH S GB 300/3 BES 0010019223 Benchmark Vaillant is a licensed member of the Benchmark Scheme. Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers are provided with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with the manufacturer’s instructions by a competent person approved...
  • Page 6: Hot Water Association

    Hot Water Association Install the product in such a way that the thermostat and immersion heater can be accessed easily. Vaillant is a full member of the Hot Water Association and – Leave sufficient space around the product for installing, promotes the scheme in association with its cylinder range.
  • Page 7: Unpacking The Product

    ▶ Protect the product and its components. ▶ Do not weld the connection pieces if these have been screwed into the pipe fittings. 0020221298_04 auroSTOR Installation and maintenance instructions...
  • Page 8 Secondary circuit return cylinder may cause the cylinder to burst. ▶ Ensure that the expansion relief valves are not blocked. ▶ Ensure that there is no isolation valve between the safety group and the cylin- der. Installation and maintenance instructions auroSTOR 0020221298_04...
  • Page 9 28 mm 1.0 m ≤ 27 m 35 mm 1.4 m ≤ 9 m 28 mm 1.0 m ≤ 18 m 3/4" 22 mm 35 mm 1.4 m ≤ 27 m 42 mm 1.7 m 0020221298_04 auroSTOR Installation and maintenance instructions...
  • Page 10 If the secondary return is not installed, fit a plug on the – The position of the windows and other openings. cylinder. – The probability of prams being under the drain opening. Installation and maintenance instructions auroSTOR 0020221298_04...
  • Page 11: Electrical Installation

    Risk of material damage by drilling connection box from a third-party manufacturer in addition to through the product. the Vaillant thermostat. The product may be damaged by drilling work. ▶ Do not drill through the product. 0020221298_04 auroSTOR Installation and maintenance instructions...
  • Page 12 Connect the immersion heater as shown in the basic diagram. Attach the cover for the electrics on the cylinder. ▶ Use the grommets that are included in the scope of deliv- ery for the cylinder in the electronics box. Installation and maintenance instructions auroSTOR 0020221298_04...
  • Page 13 5.3.8 Electric connection for the primary circuit Connect the thermostat for the primary circuit and the thermal cut-out. ▶ Connect the plug (1) to the electronics box. – Diameter of the cable: 2.5 mm² 0020221298_04 auroSTOR Installation and maintenance instructions...
  • Page 14: Start-Up

    Open the manual air separator at the top of the cylinder. Let the water flow in order to remove any air bubbles. Close the manual air separator as soon as all of the air has escaped. Close the domestic hot water draw-off valves. Installation and maintenance instructions auroSTOR 0020221298_04...
  • Page 15: Troubleshooting

    The inspection may require maintenance to be carried that arrangements are made for a Maintenance Agreement. out earlier, depending on the results. Please contact Vaillant Service Solutions for further details: Inspection and maintenance work – Overview (→ Page 16) Telephone: 0330 100 3461 The immersion heater can be removed in order to inspect the inside of the cylinder.
  • Page 16: Contents C Technical Data

    (3.50 bar) (3.50 bar) (3.50 bar) Operating pressure 0.35 MPa 0.35 MPa 0.35 MPa (3.50 bar) (3.50 bar) (3.50 bar) Maximum operating pressure 0.7 MPa 0.7 MPa 0.7 MPa (7.0 bar) (7.0 bar) (7.0 bar) Installation and maintenance instructions auroSTOR 0020221298_04...
  • Page 17 VIH S GB 300/3 Connecting the immersion heater to the power 230 V / 50 Hz 230 V / 50 Hz 230 V / 50 Hz supply Immersion heater power 2.8 kW 2.8 kW 2.8 kW 0020221298_04 auroSTOR Installation and maintenance instructions...
  • Page 18 Stainless steel Stainless steel Stainless steel (1.4521) (1.4521) (1.4521) Insulation material Polyurethane Polyurethane Polyurethane Insulation thickness 50 mm 50 mm 50 mm Propellant for insulating material GWP < 5 GWP < 5 GWP < 5 Installation and maintenance instructions auroSTOR 0020221298_04...
  • Page 19: D Commissioning Checklist

    Appendix Commissioning Checklist 0020221298_04 auroSTOR Installation and maintenance instructions...
  • Page 20 The system controls have been demonstrated to and understood by the customer The manufacturer’s literature, including Benchmark Checklist and Service Record, has been explained and left with the customer Commissioning Engineer’s Signature Customer’s Signature www.centralheating.co.uk © Heating and Hotwater Industry Council (HHIC) Installation and maintenance instructions auroSTOR 0020221298_04...
  • Page 21 Company name: Company name: Telephone No: Telephone No: Comments: Comments: Signature Signature SERVICE 09 SERVICE 10 Date: Date: Engineer name: Engineer name: Company name: Company name: Telephone No: Telephone No: Comments: Comments: Signature Signature 0020221298_04 auroSTOR Installation and maintenance instructions...
  • Page 22: Index

    Qualification................3 Regulations ................4 Safety device................. 3 Safety group ................8 Serial number ................ 5 Spare parts................15 Tool ..................4 Transport ................4 Troubleshooting..............15 Unpacking the product ............7 Voltage .................. 3 Installation and maintenance instructions auroSTOR 0020221298_04...
  • Page 24 0020221298_04 0020221298_04 29.11.2019 Supplier Vaillant Ltd. Nottingham Road Belper Derbyshire DE56 1JT Telephone 0330 100 3461 [email protected] www.vaillant.co.uk © These instructions, or parts thereof, are protected by copyright and may be reproduced or distributed only with the manufacturer's written consent. Subject to technical modifications.

Table of Contents