Si12-994
11.Removal of Compressor
Procedure
Step
1
Remove the terminal
cover.
Disconnect the
2
compressor lead wires.
Remove the 2 sheets of
3
putty.
Remove the 3 nuts.
4
Removal Procedure
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Terminal cover
Compressor lead wire
U (red)
V (yellow)
Terminal nameplate
(R16026)
N
(brown)
W (blue)
(R2205)
Putty
(R10373)
Removal of Compressor
Points
27