Sterilization Mode - Panasonic WH-SXC09H3E8 Service Manual

Air-to-water
Table of Contents

12.13 Sterilization Mode

Purpose:
To sterilize water tank by setting the required boiling temperature.
-
Remote control setting
Days for sterilization function to start can be select.
-
Time of selected day to start sterilization function.
-
Boiling temperature (External heater is 55°C ~ 75°C, Internal heater is 55°C ~ 65°C)
-
Maximum operation time is 5 minutes to 1 hour.
-
Start condition
Tank connection set to "YES" by remote control
-
Sterilization function selects "YES".
-
Sterilization signal received from remote controller by timer.
-
Tank mode request ON.
-
Stop condition
When boiling timer is completed. Boiling timer (Remote control set maximum operation time) start counting
-
once tank achieve boiling set temperature OR
After 8 hours of operation since sterilization start.
-
Tank mode request OFF.
-
Control content:
During sterilization function activation time, target tank set temperature will internally change to boiling set
-
temperature.
During sterilization activates, heat pump and heater (external or internal) will operate as normal tank mode to
-
achieve the boiling set temperature.
Sterilization operation will end when stop condition is fulfill.
-
After sterilization is complete, tank set temperature will resume to normal operation.
-
* Tank temperature may not achieve boiling set temperature if tank heater is select OFF OR external compressor
switch.
126

Hide quick links:

Table of Contents
loading

This manual is also suitable for:

Wh-sxc12h9e8Wh-sxc16h9e8Wh-ux09he8Wh-ux12he8Wh-ux16he8

Table of Contents