Air-Conditioners
PEAD-RP35,50,60,71,100,125,140JAQ
PEAD-RP35,50,60,71,100,125,140JALQ
OPERATION MANUAL
For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme
gründlich durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du
climatiseur.
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado
para garantizar un uso seguro y correcto.
ISTRUZIONI DI FUNZIONAMENTO
Leggere attentamente questi istruzioni di funzionamento prima di avviare l'unità, per un uso corretto e sicuro
della stessa.
BEDIENINGSHANDLEIDING
Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de
airconditioner gebruikt.
DRIFTSMANUAL
Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används.
DRIFTSMANUAL
Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug.
MANUAL DE OPERAÇÃO
Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a
unidade de ar condicionado.
E°XEIPI¢IO O¢H°IøN XPH™Eø™
°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ¯Ú‹Ûˆ˜ ÚÈÓ ı¤ÛÂÙ ÛÂ
ÏÂÈÙÔ˘ÚÁ›· ÙË ÌÔÓ¿‰· ÎÏÈÌ·ÙÈÛÌÔ‡.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
Для обеспечения правильного и безопасного использования следует ознакомиться с инструкциями, указанными в
данном руководстве по эксплуатации, тщательным образом до того, как приступать к использованию кондиционера.
‹fiLETME ELK‹TABI
Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› iflletmeden önce bu
elkitab›n› dikkatle okuyunuz.
FOR USER
FÜR BENUTZER
POUR L'UTILISATEUR
PARA EL USUARIO
PER L'UTENTE
VOOR DE GEBRUIKER
FÖR ANVÄNDAREN
TIL BRUGER
PARA O UTILIZADOR
°π∞ ∆√¡ Ã∏™∆∏
ДЛЯ ПОЛЬЗОВАТЕЛЯ
KULLANICI ‹Ç‹N
English
Deutsch
Français
Español
Italiano
Nederlands
Svenska
Dansk
Português
∂ÏÏËÓÈο
Русский
Türkçe
Table of Contents
loading

Summary of Contents for Mitsubishi Electric PEAD-RP35JAQ

  • Page 1 Air-Conditioners PEAD-RP35,50,60,71,100,125,140JAQ PEAD-RP35,50,60,71,100,125,140JALQ OPERATION MANUAL FOR USER English For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH FÜR BENUTZER Deutsch Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen. MANUEL D’UTILISATION POUR L’UTILISATEUR Français...
  • Page 2: Table Of Contents

    This symbol mark is according to the directive 2002/96/EC Article 10 Information for users and Annex IV. for WEEE) Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and reused. This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your house- hold waste.
  • Page 3 2. Parts Names ■ Wired Remote-Controller (PAR-21MAA option) “Sensor” indication Display Section Displayed when the remote controller sensor is used. Day-of-Week For purposes of this explanation, Shows the current day of the week. all parts of the display are shown as lit.
  • Page 4 2. Parts Names ■ Wireless Remote-Controller (option) SET TEMPERATURE button SET TEMPERATURE button sets ON/OFF button CHECK TEST RUN and any desired room tempera- MODEL SELECT Pushing button starts operation. ture. Pushing again stops operation. NOT AVAILABLE FAN SPEED button AUTO STOP/AUTO START button TEMP ON/OFF...
  • Page 5: Screen Configuration

    3. Screen Configuration For details on setting the language for the remote controller display, refer Function Selection of remote controller Set Day/Time to section 8. Function Selection. TIME SUN The initial language setting is English. ● Function Selection of remote controller: Set the functions and ranges available to the re- mote controller (timer functions, operating restric- tions, etc.)
  • Page 6 5. Operation ■ Because the room temperature is automatically adjusted in order to ■ Press the ON/OFF button 1 again. maintain a fixed effective temperature, cooling operation is performed a • The ON lamp 1 and the display area go dark. few degrees warmer and heating operation is performed a few degrees cooler than the set room temperature once the temperature is reached Note:...
  • Page 7: Timer

    5. Operation 5.5. Ventillation The display and the fan speed of the unit will differ in the following situa- tions: s s s s s For LOSSNAY combination • When STAND BY and DEFROST are displayed. 5.5.1. For Wired Remote-controller •...
  • Page 8 6. Timer 6.1.2. Simple Timer 7. Press the appropriate Set Temperature button 3 to set the desired temperature (at 7). ■ You can set the simple timer in any of three ways. • Start time only: * Each press changes the setting, in the following sequence: No The air conditioner starts when the set time has elapsed.
  • Page 9 6. Timer 7. After completing steps 3 to 6 above, press the Filter button 4 to lock Example 2: in the value. Start the timer, with OFF time is sooner than ON time ON Setting: 5 hours Note: Your new settings will be cancelled if you press the Mode (Return) button 2 OFF Setting: 2 hours before pressing the Filter...
  • Page 10: Other Functions

    6. Timer 6.2. For wireless remote controller (option) Timer Setting TIMER AFTER AUTO OFF 1. Be sure that the “Auto Off” is visible on the screen (at 1). TEMP ON/OFF 2. Hold down the Timer Menu button B for 3 seconds, so that “Monitor” is indicated on the screen (at 4).
  • Page 11: Function Selection

    7. Other Functions 7.2. Error Codes indication When the Check button is pressed: If you have entered contact number to be called in the event of a prob- CALL:XXXX lem, the screen displays this number. (You can set this up under Func- XXX:XXX ERROR CODE °C...
  • Page 12 8. Function Selection [Function selection flowchart] Normal display (Display when the air condition is not running) Setting language (English) Hold down the E button and press the D button for 2 seconds. E Press the operation mode button. Hold down the E button and press the D button for 2 seconds. G Press the TIMER MENU button.
  • Page 13 8. Function Selection [Detailed setting] [4]–3. Mode selection setting (1) Remote controller main/sub setting [4]–1. CHANGE LANGUAGE setting • To switch the setting, press the [ ON/OFF] button D. The language that appears on the dot display can be selected. 1 Main: The controller will be the main controller.
  • Page 14 8. Function Selection [Dot display table] Selecting language English Germany Spanish Russian Italy Chinese French Japanese Waiting for start-up Operation mode Cool Heat Auto Auto(Cool) Auto(Heat) Ventilation Stand by (Hot adjust) Defrost Set temperature Fan speed Not use button Check (Error) Test run Self check Unit function selection...
  • Page 15: Emergency Operation For Wireless Remote-Controller (Option)

    8. Function Selection Selecting language English Germany Spanish Russian Italy Chinese French Japanese Room air temperature display setting Automatic cooling/heating display setting 9. Emergency Operation for Wireless Remote-controller (option) 1 ON/OFF lamp (lit when unit is operating; unlit when unit is not operat- ing) 2 Emergency operation ON/OFF...
  • Page 16: Trouble Shooting

    11. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) Air conditioner does not heat or cool well. ■ Clean the filter. (Airflow is reduced when the filter is dirty or clogged.) ■ Check the temperature adjustment and adjust the set temperature. ■...
  • Page 17 11. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) Noise is louder than specifications. ■ The indoor operation sound level is affected by the acoustics of the par- ticular room as shown in the following table and will be higher than the noise specification, which was measured in an echo-free room.
  • Page 18 This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at hand is • Low Voltage Directive 2006/95/EC based on the following • Electromagnetic Compatibility Directive EU regulations: 2004/108/EC Please be sure to put the contact address/telephone number on this manual before handing it to the customer.