Daikin Altherma 3 H MT F Installer's Reference Manual page 91

Hide thumbs Also See for Altherma 3 H MT F:
Table of Contents
In case of W1 models
EPRA08~12EAV3+W1 + ETVZ12S18+23EA6V+9W
Daikin Altherma 3 H MT F
4P634887-1 – 2021.03
1 2
L N PE
4 (Optional) Power saving function: If you want to use the power saving
function:
▪ Disconnect X804A from X805A.
▪ Connect X804A to X806A.
X805A
X806A
INFORMATION
Power saving function. The power saving function is only applicable for V3 models.
For more information about the power saving function ([9.F] or overview field setting
[E‑08]), see
"Power saving
1 Power supply cable:
▪ Route the cable through the frame.
▪ Connect the wires to the terminal block.
▪ Fix the cable with a cable tie.
Wires: 3N+GND
Maximum running current: Refer to name plate on unit.
X804A
4
function" [
 199].
9
Electrical installation
|
Installer reference guide
91