Wachendorff PH5100 Operating	 Instruction

Wachendorff PH5100 Operating Instruction

Universal display

Quick Links

Universal display PH5100
Operating instruction
Universal display PH5100
LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany
Hotline: +49 4408 804-444 Fax: +49 4408 804-100 e-mail: [email protected] www.labom.com
Operating manual
Version: 22.02.2013
[email protected] • www.labom.com
BA_074e, Rev.1C5
Operating instruction BA_074_2020-01_10.00
Page 1/3
Table of Contents
loading

Summary of Contents for Wachendorff PH5100

  • Page 1 • www.labom.com Universal display PH5100 Operating instruction Universal display PH5100 Operating manual Version: 22.02.2013 BA_074e, Rev.1C5 LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 27798 Hude Germany Operating instruction BA_074_2020-01_10.00 Hotline: +49 4408 804-444 Fax: +49 4408 804-100 e-mail: [email protected] www.labom.com...
  • Page 2: Table Of Contents

    Error messages, default and calibration ................14 10.1 Error messages ......................14 10.2 Calibration and factor setting ..................15 Copyright ..........................15 Disclaimer ..........................15 Other regulations and standards ..................15 Techncal Support .........................15 - 2 - BA_074e, Rev.1C5 Operating instruction BA_074_2020-01_10.00 Universal panel indicator PH5100 Page 2/15...
  • Page 3: Introduction

    Remaining hazards Units from the LABOM universal panel meter PH5100 are state of the art and safe to operate. A risk of danger can occur when deployed and operated improperly by untrained personnel. In this manual remaining hazards are marked by the following warning symbol:...
  • Page 4: Ce-Conformity

    The universal panel meter PH5100 is a quite versatile process indicator with totalizing function. With a wide list of input types - thermocouples, thermo-resistance, voltage and current the PH5100 is capable of measuring the majority of the variables and sensors encountered in industrial processes.
  • Page 5    presents problems such as interrupted sensor, bad connection, etc. Table 02: Alarm functions Note: The figures are also valid for Alarm 2 (SPA2). - 5 - BA_074e, Rev.1C5 Operating instruction BA_074_2020-01_10.00 Universal panel indicator PH5100 Page 5/15...
  • Page 6: Blocking Initial Of The Alarm

    Reset minimum and maximum values                        - 6 - BA_074e, Rev.1C5 Operating instruction BA_074_2020-01_10.00 Universal panel indicator PH5100 Page 6/15...
  • Page 7: Over Flow Alarm

                       powered off these information is not stored. 4.13 24 VDC auxiliary voltage source The standard version of the PH5100 provides an auxiliary power supply (24 VDC) for exciting field transmitters (terminal 13 on the rear panel). 4.14 Interface USB-Port (virtual COM-Port) to program the digital display.
  • Page 8: Electrical Installation

    • • • • It is recommended to use RC FILTERS (0,1uF in series with 100 ohms) to suppress the noise generated by contactors coils, solenoids, etc. - 8 - BA_074e, Rev.1C5 Operating instruction BA_074_2020-01_10.00 Universal panel indicator PH5100 Page 8/15...
  • Page 9: Operation

    When the controller is powered up, its firmware version is displayed for 3 seconds, after which the PH5100 starts normal operation, when the value of PV is displayed and the outputs are enabled. Before the indicator is ready to be used in a given process, it requires some basic configuration, consisting of assigning values to the parameters according to the desired behavior.
  • Page 10: Description Of The Parameters

                Adjustable between 0 and 20. At 0 (zero) it means filter turned off and 20 Filter - 10 - BA_074e, Rev.1C5 Operating instruction BA_074_2020-01_10.00 Universal panel indicator PH5100 Page 10/15...
  • Page 11: Totalizing Cycle

    Defines if the total value is restored or reset on indicator power up Reset Reset Totalizer     No reset of the Totalizer     - 11 - BA_074e, Rev.1C5 Operating instruction BA_074_2020-01_10.00 Universal panel indicator PH5100 Page 11/15...
  • Page 12: Calibration Cycle

    Serial number 4 least significant digits.        Password protection The PH5100 indicator provides means for protecting the parameters configurations, not allowing modifications to the parameters values, avoiding tampering or improper manipulation. The parameter Protection ( ) in the Calibration level determines the protection strategy, limiting ...
  • Page 13 As an example, for the equipment with serial number 07154321, the master password is 9 3 2 1. The indicator serial number can be obtained by pressing for 5 seconds. - 13 - BA_074e, Rev.1C5 Operating instruction BA_074_2020-01_10.00 Universal panel indicator PH5100 Page 13/15...
  • Page 14: Specifications

      Connection and/or configuration errors. Check the wiring and the configuration.     Other error messages may indicate hardware problems requiring maintenance service. - 14 - BA_074e, Rev.1C5 Operating instruction BA_074_2020-01_10.00 Universal panel indicator PH5100 Page 14/15...
  • Page 15: Calibration And Factor Setting

    If you have any problems or questions please contact us at: LABOM Mess- und Regeltechnik GmbH Im Gewerbepark 13 • 27798 Hude • Germany Phone: +49 4408 804-0 • Fax -100 [email protected] www.labom.com - 15 - BA_074e, Rev.1C5 Operating instruction BA_074_2020-01_10.00 Universal panel indicator PH5100 Page 15/15...