Cabling Requirements - Huawei RRU3260 Installation Manual

Hide thumbs Also See for RRU3260:
Table of Contents
RRU3260
Installation Guide

9.1 Cabling Requirements

Cables must be laid out according to the specified cabling requirements to prevent signal
interference.
General Cabling Requirements
Bending radius requirements
l
l
l
l
l
l
Cable binding requirements
l
l
l
l
l
l
Security requirements
l
l
l
Indoor cabling requirements
l
Issue 10 (2015-12-30)
NOTE
If a cable listed below is not required, skip the cabling requirements of the cable.
The bending radius of a 7/8'' feeder must be greater than 250 mm (9.84 in.), and the
bending radius of a 5/4'' feeder must be greater than 380 mm (14.96 in.).
The bending radius of a 1/4'' jumper must be greater than 35 mm (1.38 in.). The bending
radius of a super-flexible 1/2'' jumper must be greater than 50 mm (1.97 in.), and the
bending radius of an ordinary 1/2'' jumper must be greater than 127 mm (5 in.).
The bending radius of a power cable or PGND cable must be at least three times its
diameter.
The bending radius of a fiber optic cable is at least 20 times of its diameter, and the
bending radius of a breakout cable is at least 30 mm (1.18 in.).
The bending radius of an E1/T1 cable must be at least three times its diameter.
The bending radius of a signal cable must be at least five times its diameter.
Cables of the same type must be bound together.
Different types of cables must be separately laid out and bound, with a minimum
distance of 30 mm (1.18 in.) from each other.
The cables must be bound tightly and neatly. The sheaths of the cables must not be
damaged.
The cable ties must face the same direction, and those at the same horizontal line must be
in a straight line.
The excess of the indoor cable ties is cut off. The excess of 5 mm (0.197 in.) of the
outdoor cable ties is reserved, and the cut surfaces are smooth without sharp edges.
After cables are installed, labels or nameplates must be attached to the cables at their
ends, curves, and interconnection positions.
When routing cables, avoid sharp objects, for example sharp edges on the wall. If
necessary, use tubes to protect the cables.
When routing cables, keep the cables away from heat sources and use heat insulation
materials to insulate the cables from the heat sources.
Reserve a proper distance (0.1 m or 3.937 in. is recommended) between equipment and
cables especially at the cable curves to protect the cables and equipment.
Route each cable into the room through the feeder window.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
9 Installing RRU Cables
87
Table of Contents
loading

Table of Contents