Closing The Cover Plate Of An Rru Cabling Cavity - Huawei RRU3260 Installation Manual

Hide thumbs Also See for RRU3260:
Table of Contents
RRU3260
Installation Guide
Step 3 Route the cables according to the instructions in
cable ties to bind the cables.
Step 4 Label the installed cables according to the instructions in Attaching an L-Shaped Label.
----End

9.12 Closing the Cover Plate of an RRU Cabling Cavity

This section describes the procedure for closing the cover plate of an RRU cabling cavity.
Procedure
Step 1 Close the clips for the installed cables. Use an M4 torque screwdriver to tighten the screws on
each clip to 1.4 N·m (12.39 lbf·in.), as shown in
Ensure that the exposed shield layer of the power cable is properly tightened using the clip.
Issue 10 (2015-12-30)
Figure 9-28 Installing CPRI optical cables for single-fiber bidirectional optical modules
NOTICE
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
9 Installing RRU Cables
9.1 Cabling
Requirements, and then use
Figure
9-29.
113
Table of Contents