6.11 Two Thermistor Control

This is the function to select the temperature sensor to judge the room temperature.
Temperature sensor selection
01
Remote controller
02
Indoor unit
03
2TH
h The function of 2TH has different operation characteristics according to the product.
If pressing
1
remote controller setter setup mode.
- If pressing once shortly, it enters into user setup mode.
Please press more than 3 seconds for sure.
If moving to room temperature perception sensor selection menu by
2
pressing
Set Thermistor value by pressing
3
02: Indoor, 03: 2TH)
Function Code
4
Press
5
Pressing
After setup, it automatically gets out of setup mode if there is no button input
for 25 seconds.
When exiting without pressing set button, the manipulated value is not
reflected.
Operation in remote controller temperature sensor
Operation in indoor unit temperature sensor
Operation of higher temperature by comparing indoor unit's and wired remote
Cooling
controller's temperature.
(There are products that operate at a lower temperature.)
Operation of lower temperature by comparing indoor unit's and wired remote
Heating
controller's temperature.
button long for 3 seconds, it enters into
button, it indicates as picture below.
Thermistor setting
button to save.
button will exit settings mode.