Boost Mode Switch; Twin Tech (Parallel Running Terminal) - Yamaha EF2200iS Owner's Manual

Hide thumbs Also See for EF2200iS:
Table of Contents
1
1
4
light "B" flashes 3 times, it shows that the total opera-
tion time is about 2300 hours.
TIP
Hour meter does not function when the generators are
in parallel operation (Twin Tech).

Boost Mode Switch

The boost mode switch increases engine speed (r/min)
temporarily (for approximately 60 seconds). When
using devices that require a large starting current, such
as a compressor or a submersible pump, use this
switch.
To enter the boost mode, push the boost mode switch
for 3 seconds. To exit the boost mode, push the boost
mode switch for 3 seconds again.
1. Boost mode switch
TIP
After approximately 60 seconds of the boost mode, the
generator will return to the normal mode automatically.

Twin Tech (Parallel Running Terminal)

Two EF2200iS generators can be operated in parallel
to increase the rated output to 3.6 kVA and the rated
current to 30.0 A. For parallel operation, use only a
special Twin Tech cable (optional equipment) approved
by Yamaha; contact your Yamaha dealer for the proper
Twin Tech cable.
The handling, operation procedure and the notes on
usage are described in the Twin Tech cable owner's
manual included in the Twin Tech cable. Consult a
Yamaha dealer for this Twin Tech cable.
1. Twin Tech cable
Controls and Features