Page 2
All product and brand names are the service marks, trademarks, registered trademarks, or registered service marks of their respective owners. Printed in the United States of America. Honeywell reserves the right to change any information in this document at any time without prior notice.
DO NOT ACCEPT VERBAL APPROVALS, BECAUSE THEY ARE NOT VALID. Honeywell never recommends using the PW-7000 or related products for use as a primary warning or monitoring system. Primary warning or monitoring systems should always meet local fire and safety code requirements.
Inc. Copyright laws of the United States protect all information in this document or in the software product itself. Note: Any use of this product is subject to the terms and acceptance of the Honeywell, Inc. Software Agreement. Please request a copy from Honeywell, Inc., and review the agreement carefully.
Product or the negligence of Honey- well, its agents, or its employees. Customer shall hold harmless and indemnify Honeywell from and against all claims, demands, losses, and liability arising out of damage to property or injury to...
• If any other defect is apparent, call for a return authorization. Shipping Instructions To ship equipment back to Honeywell, Inc.: Step 1. Contact the customer service department at 800-323-4576 before returning equipment. When you call please have available: •...
All Products sold or licensed by Honeywell include a warranty registration card which must be completed and returned to Honeywell by or on behalf of the end user in order for Honeywell to provide warranty service, repair, credit or exchange.
Page 10
This page is intentionally left blank viii PW-7000 Input Module (PW7K1IN) Installation Guide, Document 800-25674V1...
CHAPTER PW-7000 INPUT MODULE Description The PW-7000 Input Module provides connections for 16 supervised inputs and two relay outputs. You can either mount the board in a rack or open and flat. If you rack-mount the board, only one edge is accessible for wiring; however, a flat mount increases the amount of available I/O slightly but significantly decreases the num- ber of boards that can be mounted in one enclosure.
Specification The Input Board is for use in low voltage, class 2 circuits only. Primary power: 12VDC + 10%, 250mA maximum Relay contacts: Relays 0 and 1 outputs, Form-C, 2A @ 30VDC, resistive Inputs: • 16 supervised, End of Line resistors 1k ohm ± 1% tolerance •...
Selection 9,600 BPS 19,200 BPS 38,400 BPS* Not Used* * = Default LED Operation The Input Board uses two onboard LEDs (D1 and D2) to provide status information during the power-up sequence as well as during normal operation. Table 3: PW-7000 Input Module Onboard LED Settings Mode LED D1 LED D2...
Table 4: Additional PW7000 Input Module LEDs LED number Description Input 0 status Input 1 status Input 2 status Input 3 status Input 4 status Input 5 status Input 6 status Input 7 status Input 8 status Input 9 status Input 10 status Input 11 status Input 12 status...
For wiring to an RS-485 port: Step 1. TR+ is the plus side of the transmit and receive differential signal. Step 2. TR- is the negative side of the transmit and receive differential signal. Step 3. GND is the signal ground. The wiring for this signal is required and NOT optional.
Alarm Contact Wiring Inputs 0 to 15 may be configured to use normally open or normally closed contacts and non-supervised or supervised (with standard ±1 tolerance 1K ohm). All 16 inputs can be configured to monitor general-purpose alarm sensors or can be used as control inputs.
Mounting Options This board can be mounted on-edge in the rack-mount enclosure provided by Honeywell or it can be mounted flat against any surface using standoffs under the mounting holes provided in each of the four corners of this board.
Wiring Diagram for Connectors 10 through 12 Figure 2: PW-7000 Input Module Wiring: Connectors 10-12 INPUT BOARD Temper Switch (In CLOSED position Relay 0 NO when Cabinet Door is closed) Relay 0 C Tamper Relay 0 NC Ground Power Fail IN0 Common Relay 1 NC IN1 Common...
Page 22
Honeywell Integrated Security, 135 W. Forest Hill Avenue Oak Creek, WI 53154 United States 800-323-4576 414-766-1798 Fax www.security.honeywell.com Discover | Customer Portal Self-Service Product Support and Learning Management System https://honeywelldiscovertraining.com/login/discover/default.asp ™ YouTube | Honeywell Help and Support https://www.youtube.com/channel/UCBEL6ouNV_LN5lEpYRujMTg/featured Document 800-25674V1...