Bosch CM430S Installer's Reference Manual

Bosch CM430S Installer's Reference Manual

Lan to ethernet converter module

Quick Links

Installer
Reference Guide
Rev 1.2
®
CM430S
RS485 LAN To Ethernet
Converter Module
loading

Summary of Contents for Bosch CM430S

  • Page 1 Installer Reference Guide Rev 1.2 ® CM430S RS485 LAN To Ethernet Converter Module...
  • Page 2: Converter Module

    Converter Module The CM430S allows you to extend the control panels RS485S LAN across a local network. Table 1: shows the panel and panel fi rmware which are compatible with the CM430S converter module. MENU 7-7-0, Option 5 (Extend LAN Fail) must be set when using the CM430S.
  • Page 3 CM430S Confi guration (Point to Point) Connect a module to your computer and power the module using 12VDC. Open your browser and enter 192.168.1.200 (Factory set) and press [Enter]. If the unit is reset by the user, then its default address will be 192.168.1.254 A window will be displayed prompting you to enter the password (default = 123456).
  • Page 4: Tcp Client

    The CM430S module at the panel (Location 1) has to be set to ‘TCP Server’ , and the CM430S module at the destina- tion (Location 2) is to be set as ‘TCP Client’ . The table below is an example of confi guring the Client and Server modules.
  • Page 5 CM430S Star Confi guration An array of 17 x CM430S modules (1xServer, 16x Clients) can be used if more then one location is needed. This con- fi guration will need to go through a LAN switch that has a backup power supply. Each Remote location will require a local power supply with backup battery to maintain connectivity during power outages.
  • Page 6 Location 1 Location 2 Location 3 Location 4 Option SERVER CLIENT CLIENT CLIENT Device IP 192.168.1.5 192.168.1.6 192.168.1.7 192.168.1.8 Subnet Mask 255.255.255.0 255.255.255.0 255.255.255.0 255.255.255.0 Gateway 192.168.1.5 192.168.1.5 192.168.1.5 192.168.1.5 Primary DNS 168.95.1.1 168.95.1.1 168.95.1.1 168.95.1.1 Work Mode TCP Server TCP Client TCP Client TCP Client...
  • Page 7 CM430S Reset The CM430S modules can be reset whilst powered up by using a thin screwdriver and sliding the Reset switch from OFF to ON position, then after 2-3 seconds, back to the OFF position. This will reset the device IP to 192.168.1.254 CM430S Specifi...
  • Page 8 IGIFLE Unit 5, 8 Millennium Court Silverwater NSW 2128 AUSTRALIA Phone: (+612) 97417000 Facsimile: (+612) 97417042 www.digiflex.com.au Our Vision Is Your Peace Of Mind Copyright © 2002-2019 Digifl ex Pty Ltd P/N : CM430SIRG...